B4) CLOSING HAMMER:
The control unit is supplied by the manufacturer with the
Closing Hammer Function disabled. If you want to enable
the Closing Hammer function at maximum power, proceed
as follows: set SEL and SET to display B4 then press SET
to select the function. At the same time DOT 1 will start to
flash, press SET to change the function, DOT 2 will
remain permanently lit and the operation will be complete.
If, however, you want to enable the Water Hammer
function with the force set via trimmer VR2, proceed as
follows: set SEL and SET to display B3 then press SET to
select the function. At the same time DOT 1 will start to
flash, press SET and at the same time DOT 1 will start to
flash quickly, press SET to change the function, DOT 2
will remain permanently lit and the operation will be
complete.
Repeat the operation to restore the initial configuration.
Accordingly
the
control
Deceleration during closing, will reach (after having
completed the deceleration closing phase) a time of 1
second with power relative to the choice selected in order
to overcome the gate installed.
B5) FOLLOW ME :
The control unit is supplied by the manufacturer with the
Follow Me function disabled. If you want to enable the
function, proceed as follows: set SEL and SET to display
B5 then press SET to select the function. At the same
time DOT 1 will start to flash, press SET to change the
function, DOT 2 will remain permanently lit and the
operation will be complete. This way, the control unit will
close the gate immediately instead of respecting the
operating logic set, if it detects transit via activation of the
photocell connected to the DS input during the Opening,
Pause and Closing phases.
Repeat
the
procedure
configuration.
B6) Remote programming of radio control :
The control unit allows the transmission code to be
programmed,
without
programming buttons directly on the control unit, but
remotely.
The Radio-control can be remotely programmed as
follows: continuously sending a previously-memorised
radio-control code for more than 10 seconds. At this point
the control unit switches to programming mode, as
described above for the TX CODE in the A4 menu.
The control unit is supplied by the manufacturer with the
remote transmission code programming disabled. If you
want to enable the function, proceed as follows: set SEL
and SET to display B6 then press SET to select the
function. At the same time DOT 1 will start to flash, press
SET
to
change
the
permanently lit and the operation will be complete.
Repeat
the
procedure
configuration.
B7) ELECTRONIC BRAKE :
The control unit is supplied by the manufacturer with the
electronic brake function disabled. If you want to enable
the function, proceed as follows: set SEL and SET to
display B7 then press SET to select the function. At the
same time DOT 1 will start to flash, press SET to change
the function, DOT 2 will remain permanently lit and the
operation will be complete.
Accordingly,
the
control
advancement by inertia, when there is a stop or command
to change the direction of motion. Repeat the procedure
to restore the previous configuration.
unit,
if
functioning
to
restore
the
using
the
SEL
and
function,
DOT
2
will
to
restore
the
unit
slows
down
B8) SOFT START :
The control unit is supplied by the manufacturer with the
Soft Start function disabled. If you want to enable the
function, proceed as follows: set SEL and SET to display
B8 then press SET to select the function. At the same
time DOT 1 will start to flash, press SET to change the
function, DOT 2 will remain permanently lit and the
operation will be complete. Accordingly, every time the
gate starts motion the control unit will control motor start-
up, increasing the power gradually from minimum to
maximum in the first two seconds of operation. Repeat the
procedure to restore the previous configuration.
B9) SOFT STOP :
The control unit is supplied by the manufacturer with the
Soft Stop function disabled. If you want to enable the
function, proceed as follows: set SEL and SET to display
with
B9 then press SET to select the function. At the same
time DOT 1 will start to flash, press SET to change the
function, DOT 2 will remain permanently lit and the
operation will be complete. This way, at the end of
movement, the control unit will gradually bring the force
down to zero within 2 seconds.
Repeat the procedure to restore the previous configuration.
CONFIGURATIONS MENU " C "
The control unit is supplied by the manufacturer with the
possibility of selecting a number of important functions.
----------------- CONFIGURATIONS MENU " C " --------------
Digit Reference
C1) BL Input = DS2
C2) FC Inputs ( 1-4 ) = DS ( 1-4 )
C3) PUL = OPEN / PED = CLOSED NO
previous
C4) PRE-FLASHING
C5) COURTESY LIGHT
C6) PAUSE LAMP
C7) DECELERATION
C8) DS1 PHOTOCELLS TEST
SET
C9) DS2 PHOTOCELLS TEST
C1) BL Input Selection:
The default settings of the control unit have BL input
operation for connection of a Block button (NC). If you
want to select BL input operating mode as DS2, proceed
as follows: set SEL and SET to display C1 then press SET
to select the function. At the same time DOT 1 will start to
flash, press SET to change the function, DOT 2 will
remain permanently lit and the operation will be complete.
Repeat
configuration.
C2) 4 x FC Inputs Selection:
remain
The default settings of the control unit have operation of
limit switch inputs FA1, FC1, FA2, FC2 for connection of
previous
the limit switches (NC) for the two motors connected. If
you want to select Limit Switch operation as Safety
Devices, proceed as follows: set SEL and SET to display
C2 then press SET to select the function. At the same
time DOT 1 will start to flash, press SET to change the
function, DOT 2 will remain permanently lit and the
operation will be complete.
Repeat
configuration.
This way, the control unit changes operation of the 4 Limit
switch inputs in 4 Safety Devices inputs with the following
gate
operation:
FC AP1 ( Safe opening ) :
If the device trips during closing, it is ignored. If it trips
during opening, it Stops + gate motion is reversed for 2
sec.
14
DOT 2 Off
NO
NO
NO
NO
NO
NO
NO
NO
the
procedure
to
restore
the
procedure
to
restore
Rev. 1.1
DOT 2 On
YES
YES
YES
YES
YES
YES
YES
YES
YES
the
previous
the
previous
17/04/2018

Publicidad