Replacing The Filters - Black+Decker CUA525BH Traducción De Las Instrucciones Originales

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 35
If the appliance detects a damaged battery, the charging
indicator will flash at a fast rate when the appliance is on
charge. Proceed as follows:
Take the appliance and the charger to be tested at an
u
authorised services centre.
Note: It may take as long as 60 minutes to determine that
the battery is defective. If the battery is too hot or too
cold, the LED will alternately blink, fast and slow, one
flash at each speed and repeat.
Emptying the dust bowl (Fig. K, L, N)
Holding the unit over a suitable waste receptacle, press
u
the dust bowl release button (6a) to release the dust bowl
lid (6) as shown in figure K.
Push the compacting handle (19) down to empty the
u
contents of the dust bowl (5a) as shown in figure L.
Compacting the contents of the dust bowl
(Fig. M, N)
With the dust bowl lid (6) closed, push the compacting
u
handle down to compact the contents of the dustbowl (5a)
to maximise dust collection as shown in figure N.
N1 = Before compacting. N2 = After compacting.
Releasing the dust bowl (Fig. O, P)
Note: The dust bowl can be released either from the unit while
it is in chassis mode, as shown in figure O, or when being
used in the lift away canister vac mode, as shown in figure P.
Press the dust bowl release lever (20) down to release the
u
dust bowl.
Free the dust bowl (5a) from the lift away canister vac (5).
u
Using the dust bowl handle (21) and holding the unit over
u
a suitable waste receptacle, press the dust bowl release
button (6a) to release the dust bowl lid (6) and push the
compacting handle (19) down to empty the contents of the
dust bowl (5a) as shown in figure Q .
Cleaning the dust bowl filters (Fig. R,S,T)
Press the dust bowl release lever (20) down to release the
u
dust bowl as shown in figure O.
Lift the filter assembly (22) from the dust bowl (5a) by
u
rotating anti clockwise as shown in figure R.
Note: The CUA525BHP unit pre filter is supplied with a scent-
ed disc in a foil wrapper (22a) which can be attached allowing
for a pleasing odour to be released when the appliance is in
use.
The filter (23) can now be lifted out of the pre filter (22) as
u
shown in figure T.
The dust bowl can be seperated into two parts, (5b) and
u
(5c), for a more thorough cleaning as shown in figure S.
Rinse out the dust-bowl with warm soapy water.
u
Wash the filters with warm soapy water (Fig. W, X).
u
(Original instructions)
Make sure the filters are dry
u
Refit the filters into the appliance and ensure that they are
u
correctly seated.
Close the dust-bowl (5a). Reconnect to the lift away
u
canister vac making sure the release latch (20) clicks into
place.
Cleaning the hand held vac exhaust filters (Fig. U,
V)
Lift off the filter access panel (23), Exposing the filter
u
chamber (25).
The filter (24) can now be removed for cleaning.
u
Note: The CUA525BHA unit is equipped with a HEPA filter
(26) to aid in protection from allergies.
Both types of filters can be cleaned with warm soapy
u
water (Fig. W, X).
Carrying strap (Fig. Y)
A carrying strap (2a) is supplied to allow easier utilisation of
the hand held vac. This is easily connected to the handle (2)
via a velcro fastener as shown in figure Y.
Maintenance
Warning! Before performing any maintenance or cleaning on
the appliance, unplug the appliance.
From time to time wipe the appliance with a damp cloth.
Do not use any abrasive or solvent-based cleaner. Do not
immerse the appliance in water.
Your BLACK+DECKER cordless appliance has been designed
to operate over a long period of time with a minimum of main-
tenance. Continuous satisfactory operation depends upon
proper tool care and regular cleaning.
Warning! Before performing any maintenance on cordless
appliances:
Unplug the charger before cleaning it. Your charger does
u
not require any maintenance apart from regular cleaning.
Regularly clean the ventilation slots in your appliance/
u
charger using a soft brush or dry cloth.
Regularly clean the motor housing using a damp cloth. Do
u
not use any abrasive or solvent-based cleaner.

Replacing the filters

The filters should be replaced every 6 to 9 months and when-
ever worn or damaged. Replacement filters are available from
your BLACK+DECKER dealer.
CUABF10 - Standard
Filter Kit
CUAHF10 - HEPA Kit
ENGLISH
Pleated Filter + Foam Exhaust
HEPA Pleated Filter + HEPA
Exhaust