KDP8 - 2/3 wires detector
Motion detector wall switch
Flush mount with European standard junction box
• Disassemble the detector head and the plastic frame from the power box.
• Unscrew the terminal and refer to the wiring diagram (See FIG.6 - FIG.10) to
insert the power cables into the corresponding terminal pin jack. Please be
noted to strip off 6-8MM of cable sheathing by tool (See FIG.12).
• Screw the terminal and make sure the wires are securely fixed.
• Put the wired power box into the European junction box (See FIG.14-A).
• Put the detector head and the plastic frame together, then insert the
combination of detector head and plastic frame into the power box by
means of hook aiming at the notch. Please ensure the pin array and female
socket are well fixed (See FIG.2).
• Supply power and refer to point 4 carrying out function test to check if
KDP8 works normally.
Surface mount with junction box (Take JB-40 for example, it is for
optional purchase)
• JB-40's 7 knock-outs are designed for various application (See FIG.13).
Break the knock-out you intend the wires going through, then insert the
wires into the corresponding hole.
Instructions manual |
26
www.grupotemper.com