Fulgor Milano FOBQ 1000 G X Instrucciones Para La Instalación Y El Uso página 54

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
Minimum distance
From wall for cover rotation
ATTENTION
• The appliance requires adequate ventilation. An open area must be provided as shown below. A ventilation grate can
be applied, if desired. This ventilation surface allows air to enter the compartment for the proper combustion of the gas
and aspiration of the combustion products. In the case of LPG, the gas is heavier than air; in the event of a leak the vent
allows the gas to leave the compartment. The air vent must be at least 700 mm x 25 mm and placed in a central position
135 mm below the mounting surface. (See drawing).
18
505
505
1025
Cut out
FRONT

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fobq 1000 g mbkFobq ll 1000 xFobq ll 1000 mbk

Tabla de contenido