Fulgor Milano FOBQ 1000 G X Instrucciones Para La Instalación Y El Uso página 56

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

EN
ATTENTION
• The LPG cylinder in the compartment below the barbecue unit, must be isolated from it by a non-combustible panel. The
compartment must comply with the requirements of EN 498.
• The ventilation requirements of EN 498 for the cylinder compartment are:
• In case of a sheet metal, or similar impenetrable, structure, ventilation openings must be made on the top and bottom the
compartment or cavity, each of which must provide a free surface of at least 200 cm2 per cylinder housed; the openings
also serve as inspection points if a rubber hose is used.
20
Minimum distance from
the rear wall 55mm
Min 300 mm
215 mm
Min 20 mm
Min 300 mm
MAX 1,5 mt

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Fobq 1000 g mbkFobq ll 1000 xFobq ll 1000 mbk

Tabla de contenido