BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _
Micropulse Transducer - Rod Style
1

Notes to the user

1.1
Validity
This guide describes the construction, function and setup
options for the BTL7 Micropulse Transducer with analog
interface. It applies to types
BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/
FA_ _ (see Type code breakdown on page 21).
The BTL7...-TB... is used in the illustrations in this user's
guide by way of example.
The guide is intended for qualified technical personnel.
Read this guide before installing and operating the
transducer.
1.2

Symbols and conventions

Individual instructions are indicated by a preceding
triangle.
► Instruction 1
Action sequences are numbered consecutively:
1. Instruction 1
2. Instruction 2
Note, tip
This symbol indicates general notes.
1.3

Scope of delivery

BTL7 transducer
Condensed guide
The magnets are available in various models
and must be ordered separately.
1.4

Approvals and markings

UL approval*
File no.
E227256
* Not for BTL7-...-FA_ _
US Patent 5 923 164
The US patent was awarded in connection with this
product.
The CE Mark verifies that our products
meet the requirements of EU Directive
2004/108/EC (EMC Directive).
www.balluff.com
The transducer meets the requirements of the following
generic standards:
EN 61000-6-1 (noise immunity)
EN 61000-6-2 (noise immunity)
EN 61000-6-3 (emission)
EN 61000-6-4 (emission)
and the following product standard:
EN 61326-2-3
Emission tests:
RF emission
EN 55016-2-3 (industrial and residential areas)
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Electrical fast transients (burst)
EN 61000-4-4
Surge
EN 61000-4-5
Conducted interference induced
by high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
By using the GL symbol, we confirm that the
marked products were type tested according to
the guidelines of Germanischer Lloyd.
The type approval is authenticated with a
certificate.
The verified test requirements cover the
environmental category "D" (closed
environments with increased heat and vibration
requirements).
Therefore, the marked products can be used
according to the specifications of the certificate
on ocean-going and inland vessels and on
offshore operations in systems subject to
mandatory type-testing.
Maximum length:
BTL7-...-TB.../ BTL7-...-TZ...: 300 mm
(500 mm when supported at the end of the
rod using slide bush
BAM PC-TL-001-D10,4-4 in bore with a
diameter of max. 13 mm)
BTL7-...-TT...: 240 mm
Severity level 3
Severity level 3
Severity level 3
Severity level 2
Severity level 3
Severity level 4
english