BTL7-A/C/E/G50_-M_ _ _ _ -T_2/3-S32/S135/KA_ _/FA_ _
Micropulse Transducer - Rod Style
7

Technical data

7.1

Accuracy

The specifications are typical values for the
BTL7-A/C/E/G... at 24 V DC and room temperature, with a
nominal length of 500 mm in conjunction with the
BTL-P-1013-4R, BTL-P-1013-4S, BTL-P-1012-4R or
BTL-P-1014-2R magnet.
The BTL is fully operational immediately, with full accuracy
after warm-up.
For special versions, other technical data may
apply.
Special versions are indicated by the suffix -SA
on the part label.
Repeat accuracy
Voltage, typical
Current, typical
Sampling rate
Dependent on the nominal length
At nominal lengths of 25 to 1200 mm
At nominal lengths of 1201 to 5000 mm
At nominal lengths of 5001 to 7620 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal lengths of 501 to 7620 mm
Temperature coefficient
1)
Voltage
Current
Max. detectable velocity
16
english
7.2
Operating temperature
Storage temperature
Relative humidity
Outer rod pressure rating
(when installed in hydraulic
cylinders)
For Ø 10.2 mm
– ≤ 2000 mm
– ≥ 2001 mm
For Ø 21 mm
Shock rating
per EN 60068-2-27
Continuous shock
±10 µm
per EN 60068-2-29
±5 µm
Vibration
per EN 60068-2-6
(note resonant frequency
2 ms
of the outer rod)
4 ms
Degree of protection per
5,7 ms
IEC 60529
Connector S32/S135 (when
±200 µm
attached)
±0.04% FS
Cable
≤ 40 ppm/K
7.3
≤ 20 ppm/K
Voltage, stabilized
10 m/s
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity protection
Overvoltage protection
Dielectric strength
(GND to housing)
Nominal length = 500 mm, magnet in the center of the measuring range
1)
2)
For
sea level.
3)
Individual specifications as per Balluff factory standard
Nominal length > 2000 mm: use only under static conditions
4)
For
5)
energy circuit as defined in UL 61010-1, a low-power source as defined in
UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
A prerequisite is that no current can flow between GND and 0 V in the
6)
event of polarity reversal.

Ambient conditions

2)
−40°C to +85°C
−40°C to +100°C
< 90%, non-condensing
≤ 600 bar
≤ 300 bar
≤ 250 bar
100 g/6 ms
3)
100 g/2 ms
3)
12 g, 10 to 2000 Hz
4)
3)
IP67
IP67

Supply voltage (external)

10 to 30 V DC
5)
≤ 0.5 V
≤ 150 mA per unit
≤ 500 mA/10 ms
per unit
Up to 36 V
6)
Up to 36 V
500 V AC
: Use in enclosed spaces and up to a height of 2000 m above
: The transducer must be externally connected via a limited-
ss