Waldbeck 10034153 Manual De Usuario página 48

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

EN
Floor protection plate
48
Mounting the exhaust pipe
The exhaust pipe outlet hole may be aligned horizontally to the heater
smoke outlet opening. In this case, the 1.5 m long flue pipe is laid outdoors.
You can also lay the 1.5 m long flue pipe on the inside (upwards to the
ceiling), in which case the outlet hole must be above the smoke outlet
opening of the heater.
After inserting the flue pipe into the wall, the gap should be filled
and sealed with heat-resistant mineral fibre. Seal the hole with high
temperature resistant cement.
Do not proceed with the installation until the cement has solidified.
Below is a standard installation drawing for reference. In this case, the
1.5 m long pipe is laid in the interior:
Termination cap
Wall thimble
Support bracket
Chimney pipe
Clean out
cover
Combustion air connection
(Minimum diameter 50  mm)

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

10034181

Tabla de contenido