Floor protection plate
48
Mounting the exhaust pipe
•
The exhaust pipe outlet hole may be aligned horizontally to the heater
smoke outlet opening. In this case, the 1.5 m long flue pipe is laid outdoors.
You can also lay the 1.5 m long flue pipe on the inside (upwards to the
ceiling), in which case the outlet hole must be above the smoke outlet
opening of the heater.
•
After inserting the flue pipe into the wall, the gap should be filled
and sealed with heat-resistant mineral fibre. Seal the hole with high
temperature resistant cement.
•
Do not proceed with the installation until the cement has solidified.
•
Below is a standard installation drawing for reference. In this case, the
1.5 m long pipe is laid in the interior:
Termination cap
Wall thimble
Support bracket
Chimney pipe
Clean out
cover
Combustion air connection
(Minimum diameter 50 mm)