In case of machine disassembly, perform the opposite operations.
CHECKING BEFORE USE
THE VIP MACHINE HAS BEEN DESIGNED FOR WORKING EXCLUSIVELY WITH WATER.
• Before any cutting operation, make sure that the water level inside the tank is correct.
7
Before using the machine, check there is power supply.
CONNECTING TO POWER SUPPLY
THE MACHINE IS TO BE CONNECTED TO THE POWER SUPPLY BY A RESIDUAL CURRENT
CIRCUIT BREAKER (RCCB) WITH THE FOLLOWING CHARACTERISTICS:
RCCB
In 16 A Id 30 mA
N.B. To ensure correct functioning, periodically check the efficiency of RCCBs by pressing the push-button on
the front of the device.
Make sure that the section of the power supply cable cores has been measured according to the starting
current and its length.
For cables up to 50 m long, a section of 4 mm2 is enough.
Before connecting the machine to the power socket, check that the power supply voltage corresponds to that
shown on the plate on the machine.
The machine must be connected to an effective earth wire.
In case of doubt, do not connect the machine.
BLADE ASSEMBLY / DISASSEMBLY
Before performing any operation or adjustment, disconnect the machine from the supply mains.
Unscrew the knobs and the locking nut on the disc cover and remove it.
Remove the blade fixing nut using the 19 mm spanner and the 5 mm Allen wrench.
8
THE BLADE FIXING NUT HAS A LEFT-HAND THREAD.
Install the new blade, checking for correct direction of rotation as clearly indicated on the tool.
Tighten the blade and put the blade cover guard back in position.
IN ADDITION TO THE KNOBS ALWAYS REASSEMBLE THE LOCKING NUT ON THE DISC COVER.
CONTROL DEVICES
The VIP machine is equipped with a control board made up of:
9
1) START BUTTON: (GREEN COLOUR)
Press the button fully to activate machine starting.
2) REGULAR STOP BUTTON: (RED COLOUR)
Press the button fully to activate machine stop.
3) DEVICE FOR DISCONNECTION FROM THE MAINS (Plug):
Machine power supply point. During the maintenance phases, take out the plug from the device in order to
disconnect the machine from the mains.