Master Audio
2.3. Connection description (CS6FR with TF-100 transformer)
• Place the TF-100 transformer on top of the ceiling speaker's pillars. Screw it
• Connect the wiring from the transformer to the speaker (use both the red and
black wire from the transformer). Red wire (16Ω) must be connected in the red
push terminal. Black wire (0) must be connected in the black push terminal
• Connect each speaker to the amplifier's output by choosing the appropriate setting
(2W or 5W or 10W or 20W for first generation transformer )
(5W or 10W or 20W or 40W for second generation transformer*)
first generation TF-100 transformer
CS Series. Version 1.0
second generation TF-100 transformer
(*scheduled June2014)
Mar14
4