GAS DRYERS
GAS REQUIREMENTS (GAS MODELS ONIY)
WARNING: To reduce
the risk o f
fire,
electric shock, or injury to persons when using this
appliance,
follow basic precautions, including
the following:
* Gas supply requirements:
As shipped from the
factory, this dryer is configured for use with natural
gas (NG), It can be converted for use with propane
(LP) gas, Gas pressure must not exceed 8 inches
wafer column far (NG), ar 13 inches wafer column for
(LP).
• A qualified
service or gas company technician
must
connect the dryer to the gas service. Failure to follow
these instructionscan result in fire, explosion, or death.
"isolate the dryer from the gas supply system by
closing its individual manual shutoff valve during any
pressure testing of the gas supply. Failure to do so can
result in fire, explosion, or death.
• Supply ilne requirements:
Your laundry roam must
have a rigid gas supply line to your dryer, in the
United States, an indivldual manual shutoff valve
MUST be installed within at least 6 ft. (1.8 m) of the
dryer, in accordance with the National
Fuel Gas Code
ANSi Z223.1 or Canadian gas insfallatlon code CSA
B149.1. A _ inch NPT pipe plug must be installed.
Failure to do so can result in fire, explosion, or death.
• if using a rigid pipe, |he rigid pipe should be ½ inch
IPS. if accep|able
under local codes and ordinances
and when acceptable to your gas suppller, _ inch
approved tubing may be used where lengths ore less
than 20 ft. (6.1 m). Larger tubing should be used for
lengths in excess of 20 ft. (6.1 m). Failure to do so can
result in fire, explosion, or death.
• Connect the dryer fo the type of gas shown on
the nameplate.
Failure to do so can result in fire,
explosion, or death.
=To prevent contamination of the gas valve, purge |he
gas supply of air and sediment before connecting
the gas supply to the dryer. Before |igh|enlng
the
connection between the gas supply and the dryer,
purge remaining
air until the odor of gas is detected,
Failure to do so can result in fire, explosion, or death.
• DO NOT use an open flame to inspect for gas leaks.
Use a noncorrosive leak detection fluid. Failure to do
so can result in fire, explosion, or death.
* Use only a new AGA- or CSA=certifled gas supply
llne with flexible stainless steel connectors. Failure to
do so can result in fire, explosion, or death.
• Securely tighten all gas connections. Failure to do so
can result in fire, explosion, or death.
• Use Teflon tape or a pipe-joint compound that is
insoluble in propane (LP) gas on all pipe threads.
Failure to do so can result in fire, explosion,
or death.
• DO NOT attempt any disassembly of the dryer;
disassembly requires the aflenfion and fl_is of
an authorized and qualified service technician or
company. Failure to follow this warning can result in fire,
explosion, or death.
=Do no|_ under any circumstances, cut or remove the
third (ground) prong from the power cord. Failure
to follow this warning can result in fire, explosion, or
death.
ELECTRICAL REQUIREMENTS
FOR
GAS MODELS ONLY
"This dryer must be plugged into a 120-VAC, 60-Hz.
grounded outlet protected by a 15-ampere fuse or
circuit breaker. Failure to follow this warning can result
in fire, explosion, or death.
• For personal safety, this dryer must be properly
grounded. Failure to follow this warning can result in
fire, explosion, or death.
"The power cord of this dryer is equipped with
a 3-preng (grounding) plug which moses with a
standard 3-prong (grounding)
wall outlet to minimize
the possibilffy of electric shock hazard from this
appliance. Failure to follow this warning can result in
fire, explosion, or death.
, Where a standard 2-prong wall outlet is encountered,
it is your personal responslblllfy
and obligation to
have it replaced with a properly grounded 3-prong
waft outlet. Failure to follow this warning can result in
fire, explosion, or death.
3-prong
grounding
type wall
3-prong J
grounding
plug
Ensure proper
ground exists
before use.