BEFORE CALLING FOR SERVICE
....
Problem .....
*c.EcK VE.T indlcato
blinking
* This warring
light is
not a dryer failure and is
not covered by the dryer
warranty. Contact a duct
cleaningservice t o set
up an opp.:_intmentto
have your exhaust system
cleaned and inspected.
The CHECK VENT
indlcafer
remains active
(blinking)
after clearing
the restriction in the vent-
ing.
Dryer will not turn on
Exhaust system is too long or has
too many turns/restrictions.
Partial blockage of the ductwork
due to lint buildup or other
foreign object.
The appliance
has detected a
restriction in the external dryer
venting.
After clearing the restriction, the
CHECK VENT system requires
multiple, consecutive cycles to
determine that the performance
value has improved before the
CHECK VENT indicator is reset.
Power cord is not properly
plugged in.
Solutions
Install a shorter or straighter duct run. See the
Installation Instructionsfor details.
Ductwork should be checked!cleaned
immediate_yo
Dryer can be used in this condition, but drying
times will be longer and energy consumption will
increase.
See the CHECK VENT INDICATOR and CHECK
VENT OPERATION sections for details regarding
this function.
if the CHECK vENT indicator remains active for
more than five cycles after the restriction has been
cleared, call for service.
Make sure that the plug issecurely plugged into e
grounded outlet matching the dryer's rating plate.
House fuse is blown, circuit
breaker has tripped, or power
outage has occurred.
Dryer does net heat
House fuse is blown, circuit
breaker has tripped, or power
outage has occurred.
Gas supply or service is turned off
(gas models only).
Greasy or di_
spotson
Clean and dirty clothes are being
€lothes
dried together.
aothes were not properly cleaned
or rinsed before being placed in
the dryer.
Drying time is not consls=
Heat settings, load size, or
fenf
dampness of clothing is not
consistent.
Reset circuit breaker or replace fuse. Do not
increase fuse capacity. If the problem is a
circuit overload, have it corrected by a qualified
electrician.
Reset circuit breaker or replace fuse. Do not
increase fuse capacity, if the problem is a
circuit overload, have it corrected by a qualified
electrician.
NOTE: Due to the design of electric dryers, it is
possible for a circuit problem to allow an electric
dryer to run without heat.
Confirm that the housegas shutoff and the dryer
gas shutoff valves are both fully open. Even if gas
is not supptied to the dryer, it will run and no error
codes will display. Verify that other gas appliances
in the home are working normally.
Only use your dryer to dry clean items.Soil from dilly
clothescan transfer to the clean clothes in the same or
later loads.
Stains on dried clothes could be stains that weren't
removed during the washing process. Make sure
that clothes are being compretely cleaned or
rinsed according to the instructionsfor your washer
and detergent. Some dimcult soils may require pre-
treating
prior to washing.
The drying time for a load will vary depending on
the type of heat used [electric, natural gas, or LP
gas), the size of the load, the type of fabrics, the
wetness of the clothes, and the condition of the
exhaust duct and lint filter. Even an unbalanced
load in the washer can cause poor spinning,
resulting in wetter crothes which will take longer to
dry.
31