Status Light Key - Leviton evr-green EVR30-B1C Guia De Instalacion

Estacion de carga de vehiculos electricos
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Status Light Key

POWER
CHARGE
OFF
OFF
GREEN
GREEN
Fast flashing
OFF
GREEN
OFF
GREEN
GREEN
OFF
Slow flashing
GREEN
GREEN
GREEN
OFF
GREEN
OFF
Slow flashing
OFF
GREEN
Auto Restart
When a charging session is interrupted due to a temporary error condition,
the AC charger will automatically re-start the charging process as soon as the error
condition returns to normal. The status indicator light flashes red until the error
condition is resolved.
Temporary error conditions include: Over Current (OCP), Over Voltage (OVP),
Under Voltage (UVP) and Over Temperature (OTP).
When a charging session is interrupted by an Over Current error, the charger will
automatically retry two times.
When a charging session is interrupted due to a CCID (Charge Circuit Interrupting
Device) trip, the charger will automatically retry after 15 minutes for up to 4 times.
Power Outage Recovery
After a power outage, the charger will automatically restart with a delay ranging
from 5 to 100 seconds. The delay is designed to avoid impacting the utility
grid when multiple chargers in the same area attempt to resume charging
simultaneously. There will be no need to authenticate the user in this situation.
FAULT
When your charging station is not plugged in, all indicator
OFF
lights are OFF. Turn on the branch circuit breaker.
When your charging station is turned on, all the indicator
RED
lights will be ON. The charging station will then undergo the
initial configuration and self-test.
RFID card has been successfully recognized.
OFF
Charging can begin (EVR30-R2C only).
RFID enabled charging is successfully occurring (EVR30-
OFF
R2C only).
The self-test is complete but the charging plug is not
OFF
inserted. Your charging station is in an idle state.
Vehicle charging in progress (All models, except EVR30-
OFF
R2C).
Your charging station is recovering from a minor fault
Slow flashing
such as over voltage (OVP), under voltage (UVP), over
RED
temperature (OTP) or over current (OCP). Wait until the
fault indicator turns OFF to resume charging.
The charging station has malfunctioned. Stop using it
RED
immediately, turn off the branch circuit breaker.
Slow flashing
Missing ground on line side.
RED
11