ACTUATOR FASTENING
As soon as the measures selected from the table, which is on the
previous page, have been marked on piers, proceed with the
following operations, considering figure 1 as a reference:
• Fasten the anchor plate
proper screws and blocks.
• Enter the ratiomotor into the anchor plate and fasten it by
means of screws
, washers
shaft must be turned downwards).
• Assembly the articulated arm and the relevant bracket as
shown in the figure.
• Fit the articulated arm into the shaft and fasten the screw
• Release the ratiomotor (see paragraph EMERGENCY LOCK
RELEASE).
• Mark the front bracket fastening points on the door
according to the previous established levels.
• Separate the front bracket F from the articulated arm.
• Fasten the bracket on the door by means of screws or
directly weld it in case the material it is made of allows it.
• Link the clamp
to the pivoted arm.
• Make several manual attempts in order to open and close
the doors by checking that no unwanted friction occurs.
• Proceed with ELECTRICAL CONNECTIONS and ADJUSTMENT
OF STOP ENDS.
• Insert the cap
, the plug
and fix the two screws.
WARNING: For the left actuator install the motor as
shown in fig.2 and repeat the above operations.
Fig. 1
Fig. 2
to the pier by making use of
and nuts
supplied (the
, the unclamping handle
.
10