3 Safety Instructions
Typ
Type of
cooling
®
ABITIG
GRIP
2
150
air
200
air
260W
liquid
260W SC
liquid
450W
liquid
450W SC
liquid
500W
liquid
Tab. 3
Product-specific torch data (EN 60 974-7)
1
According to EN 60 974-7 the value for alternating current (AC) must be given at 70% of the
tested direct current value (DC)
2 With long gas nozzle 36 mm
®
ABITIG
GRIP 260
®
ABITIG
GRIP 450
Tab. 4
Required cooling unit capacity
3 Safety Instructions
3.1 Classification
EN - 4
Load
ED
1
DC
AC
A
A
%
150
105
35
200
140
35
260
185
100
340
240
100
400
280
100
450
320
100
500
350
100
min. 800 W
min. 800 W
Observe the enclosed document Safety Instructions.
The warning signs used in the operating instructions are divided into four
different levels and are shown prior to specific work steps. Arranged in
descending order of importance, they have the following meaning:
DANGER
Describes imminent threatening danger. If not avoided, it will result in fatal or
extremely critical injuries.
WARNING
Describes a potentially dangerous situation. If not avoided, it may result in
serious injuries.
Electrode
Gas
ø
flow
max.
Max.
lenght
supply
175 mm
temp.
mm
l/min
°C
1.0 - 2.4
5 - 12
1.6 - 4.0
7 - 18
1.0 - 3.2
7 - 18
50
1.0 - 3,2
7 - 18
50
1.6 - 4.8
7 - 20
50
1.6 - 4.8
7 - 20
50
1.6 - 6.4
7 - 22
50
TIG welding torch
Cooling
Torch inlet
pressure
Min.
min.
max.
flow
l/min bar
bar
0.7
2.5
3.5
0.7
2.5
3.5
0.7
2.5
3.5
0.7
2.5
3.5
0.7
2.5
3.5