Error Message
Imp over load
Imp over load
Imp under load
Drive over load
Drive over load
Drive under load
DC input
Robot got stuck on
pool wall
Out of water
Troubleshooting
Check
Is there dirt or other
foreign matter in the
impeller?
Does the problem re-
occur on every
operation?
Does the problem re-
occur on every
operation?
Is there any interfering
dirt in the driving
belts, brushes, or drive
axles?
Does the problem re-
occur on every
operation?
Does the problem re-
occur on every
operation?
1. Is there an
electrical short,
partial or complete
disconnection?
2. Is there a visible
rupture in the
floating cable?
1. Has the robot
stopped in a
vertical position of
more than 70º?
2. Has the robot stuck
on an obstacle?
Was the robot operated
out of the water for an
extended time?
Action to Take
Unscrew the bolt that secures the protective
cover of the impeller. Turn it counter-
clockwise slightly, until it is released.
Remove any dirt around the impeller.
Replace the protective cover.
Contact the Maytronics dealer/distributor.
Contact the Maytronics dealer/distributor.
Remove any dirt or foreign bodies that might
have become entangled with the driving
belts, brushes, or drive axles.
Contact the Maytronics dealer/distributor.
Contact the Maytronics dealer/distributor.
Contact the Maytronics dealer/distributor.
Move the robot from its position and remove
the obstacle. Reactivate.
If this recurs, contact the Maytronics
dealer/distributor.
1. Check that the impeller is in order and
that its blades are not broken.
2. Reactivate. If this recurs, contact the
Maytronics dealer/distributor.
17