ENGLISH
10. INCIDENTS, C USES ND REMEDIES
The pump should be electrically isolated and
secured against unauthorised switch-on during
any repair work.
INCIDENTS
8.1 PUMP IS NOT
a) Electrical fuse defective:
RUNNING
LTHOUGH THE
b) Pump has no voltage:
CURRENT ENTRY
IS SWITCHED ON
8.2 PUMP IS
a) Cavitation due to
M KING
insufficient suction
NOISES
pressure:
a) Thermal output of the
8.3 BUILDING DOES
heating surfaces is too
NOT GET W RM
low:
F ULT SIGN LS
Code n°
E04
Undervoltage.
E05
Overvoltage.
E10
Blocking.
E11
Dry run.
E21
Overload.
E23
Short-circuit.
E25
Contacting / winding.
E30
Module
overtemperature.
E36
Out-of-step
11. SP RT P RTS
Spare parts are ordered via a local specialist dealer
and/or S LMSON customer service.
In order to avoid queries and incorrect orders, make
sure to mention all data indicated on the rating plate
when placing your order.
Subject to technical alterations.
C USES
F ULTS
Power supply too low on mains side.
Power supply too high on mains side.
Rotor blocked.
ir in the pump.
Sluggish motor.
Motor current too high.
Winding defective.
Module interior too warm.
Motor errors.
a) Check fuses.
b) Resolve the power interruption.
a) Increase the system suction pressure within the permissible
range.
Check the delivery head and set it to a lower height if
necessary.
a) Increase setpoint (cf. 8.3).
Switch off setback operation (cf. 8.5).
Set control mode to ∆p-c (cf. 8.4).
C USES
15
REMEDIES
REMEDIES
Check mains voltage.
Check mains voltage.
sk fter-Sales.
Check water quantity/ pressure.
sk fter-Sales.
sk fter-Sales.
sk fter-Sales.
Check operating conditions in
chapter 5.
sk fter-Sales.