Power Consumption - Axis Communications P3364-LV Guia De Instalacion

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 85
AXIS P3364-LV Network Camera

Power Consumption

Note
Make sure the switch on the bottom of the camera is configured to PoE class 3. The IR
illumination will not work if configured otherwise.
Product
AXIS P3364-LV
Connectors
I/O Connector
4-pin terminal block
For an example diagram, see Connection Diagrams on page 15.
Function
Pin
1
0 V DC (-)
2
DC output
Digital input
3
4
Digital
output
Audio Connector
3.5 mm audio
connectors (stereo)
PoE
Power over Ethernet IEEE 802.3af/802.3at Type 1
IR illumination on: Class 3; max 12.1 W
IR illumination off: Class 2; max 5.9 W
Notes
Can be used to power auxiliary equipment.
Note: This pin can only be used as power out.
Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate
Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used
with an inductive load, e.g. a relay, a diode
must be connected in parallel with the load,
for protection against voltage transients.
14
Specifications
0 V DC
3.3 V DC
Max load = 50 mA
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA

Publicidad

Tabla de contenido
loading