ADAPTATION TO DIFFERENT GAS TYPES
In order to adapt a cook top to a gas other than the one it is set for, follow this sequence of instructions:
remove the pan support and the burner
-
-
unfasten the injectors (M) with a socket spanner and replace them with the injectors that have a diameter suited to the new
gas type (see the "Burner Technical Details" table)
-
after finishing this sequence, replace the old setting label with the new one provided for the new injectors.
-
BURNER TECHNICAL DETAILS
Burner
Rated heat output kw
Reduced heat output kw
DE-AT reduced heat output kw
Ø INJECTOR
G30/G31 28..30/30-37mbar
G30/G31 50mbar
G20 20mbar
G25 25mbar
G25 20mbar
G110 8mbar
G120 8mbar
Ø BY-PASS:
G30/G31 28..30/30-37mbar
G30/G31 50mbar
G20 20mbar
G25 25mbar
G25 20mbar
G110 8mbar
G120 8mbar
REGULATING THE FLAME MINIMUM
Turn on the burners by setting the tap in the minimum position and remove the knob (this can be done because it is simply
pressed into place).
Take a small screwdriver and turn the tap-regulating screw anticlockwise in order to increase the gas delivery and clockwise in
order to decrease it, until a 3 or 4 mm flame is obtained.
When using LPG (in a canister) turn the by-pass clockwise until it reaches the end of its stroke.
M
SR
R
1.75
3.00
0.70
1.00
0.90
1.30
mm
0.65
0.85
mm
0.58
0.75
mm
0.97
1.15
mm
0.94
1.21
mm
1.00
1.34
mm
1.85
2.60
mm
1.80
2.40
mm
0.31
0.42
mm
0.31
0.42
mm
Adj.
Adj.
mm
Adj.
Adj.
mm
Adj.
Adj.
mm
Adj.
Adj.
mm
Adj.
Adj.
COOK TOP TECHNICAL DETAILS
TC
Model
3.8
Total Power KW
1.75
Consumption
G30
G20
0.98
G25
G110
0.77
1.35
G120
1.45
1.52
3.20
3.00
0.60
0.60
Adj.
Adj.
Adj.
Adj.
Adj.
18
HVG31
3.8
g/h
277
m³/h
0.362
m³/h
0.421
m³/h
0.862
m³/h
0.770
HVG32
4.75
346
0.453
0.526
1.078
0.962