8.4.7
Connecting pan-and-tilt unit PT40
Siemens Building Technologies
Fire Safety & Security Products
All manuals and user guides at all-guides.com
Connections
Signal
A (Rx/Tx +)
B (Rx/Tx -)
CCDA1435 interface configuration
Baud rate: 9600
Parity: None
Fig. 23
Pan-and-tilt unit PT40 – system overview
For a more detailed description of the connections please refer to Section
MX / MX DVD or Section
7
D escription of SISTORE MX 3G / MX 3G DVD.
1 4 3 H
1 4 4 H
1.
Connect the pan-and-tilt unit to the SISTORE (see
2.
Connect the camera to the SISTORE (see
Further information on this can be found in the instruction manuals for the
pan-and-tilt unit, the control unit and the camera.
3.
Start the SISTORE MX application software.
4.
Switch to configuration mode.
5.
Select the Cameras tab.
6.
Mark the checkbox PTZ.
7.
Choose the camera type from the first list box.
8.
Choose the interface from the second list box.
9.
Click Apply.
The interface for the camera is enabled.
Further information on this can be found in the SISTORE MX Configuration
Manual.
Connections
Signal
A (Rx/Tx +)
B (Rx/Tx -)
SISTORE unit
9-pin Sub-D socket
2
3
F ig. 23).
1 4 6 H
SISTORE unit
9-pin Sub-D socket
2
3
Installation
CCDA1435
Data +
Data -
6
D escription of SISTORE
1 4 1 H
1 4 2 H
F ig. 23).
1 4 5 H
CDC0501/0502 (J6)
Rx/Tx +
Rx/Tx -
43
02.2009