Connecting Miniter Interface And Access Reader - Siemens SISTORE MX Manual De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Installation

8.4.12 Connecting Miniter interface and access reader

48
Siemens Building Technologies
Fire Safety & Security Products
All manuals and user guides at all-guides.com
Fig. 29
System overview: SISTORE MX – interface und access reader (Miniter)
A
Cable (9-pin), plug-plug
2-3, 3-2
B
Null-modem cable (9-pin), plug-plug
2-3, 3-2, 4-6, 5-5, 6-4, 7-8, 8-7
For a more detailed description of the connections please refer to Section
MX / MX DVD or Section
7
D escription of SISTORE MX 3G / MX 3G DVD.
1 7 5 H
1 7 6 H
1.
Connect the interface to the SISTORE (see
For this you require the converter 485SD9R (B&B), a 9-pin cable, Sub-D,
plug-plug, connections 2–3, 3–2, and a null-modem cable, Sub-D, plug-plug,
connections 2–3, 3–2, 4–6, 5–5, 6–4, 7–8, 8–7.
2.
Connect pin 7 of the Sub-D connector through an 81-Ohm resistor to 12 V.
See the figure below:
1 Pin 7
2 +12 V
3.
Connect the access reader (Miniter) to the interface.
4.
Start the SISTORE MX application software.
5.
Switch to configuration mode.
6.
Select the System tab.
7.
Mark the checkboxes Bank mode and Cash dispenser.
8.
Click Apply.
6
D escription of SISTORE
1 7 3 H
1 7 4 H
F ig. 29).
1 7 7 H
02.2009

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Sistore mx dvdSistema mx 3gSistema mx 3g dvd

Tabla de contenido