FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE
TROUBLESHOOTING YOUR FAN.
TROUBLE
1. Fan will not start. 1. Fuse or circuit breaker blown.
2. Reversing switch in neutral position.
2. Fan sounds
1. Blades not attached to fan.
noisy.
2. Loose screws in motor housing.
3. Screws securing fan blade flanges to
motor hub are loose.
4. Screws holding blades to flanges
are loose.
3. Fan wobbles
1. Set screws in motor coupler are loose.
excessively.
2. Set screw in hanger ball / downrod assembly
is loose.
3. Screws securing fan blade flanges to motor
are loose.
4. Fan blade flanges not seated properly.
5. Hanger bracket and / or ceiling outlet box is
not securely fastened.
6. Fan blades out of balance.
4. Lamps will not
1. Loose electrical connections.
illuminate.
2. The bulb is burnt out.

12. Troubleshooting

WARNING
!
PROBABLE CAUSE
SUGGESTED REMEDY
1. Check main and branch circuit fuses or circuit breakers.
Make sure main power is turned OFF.
2. Make sure reversing switch position is all the way to
one side.
1. Attach blades to fan before operating.
Make sure main power is turned OFF.
2. Check to make sure all screws in motor housing
are snug (not over-tight).
3. Check to make sure the screws which attach
the fan flanges to the motor hub are tight.
4. Tighten screws securely.
1. Tighten both set screws securely in the motor coupler.
2. Tighten the set screw in the hanger ball / downrod
assembly.
3. Check to be sure screws which attach the fan blade
flanges to the motor are tight.
4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor.
If flanges are seated incorrectly, loosen the flange screws
and retighten according to the procedure in the section
on "Ceiling Fan Assembly".
5. Tighten the hanger bracket screws to the outlet box,
and / or secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
1. Shut off the branch circuit electricity at the fuse box or
breaker panel and check the receiver electrical connectors
for proper installation.
2. Turn the electricity off and replace the lamp with a new
6.5-Watt medium base LED bulb.