Battery Load Test Analysis
Tester Indication
During Load Test
The " GOOD " LED lights.
The " WEAK " LED
or " BAD " LED lights,
but reading remains
steady.
The " WEAK " LED
or " BAD " LED lights,
but displayed voltage
is falling.
NU-E200407_0715.indd 14

Battery Condition

Battery capacity is ok. Battery
may ormay not be fully charged
check specific gravity of the bat-
tery fluid to determine the state of
charge. If the battery is not fully
charged check for electrical drain
or possible system fault.
Recharge battery to full charge
level.
Battery capacity is not satisfac-
tory. Battery may be either defec-
tive or not fully charged. Check
specific gravity of battery fluid to
determine which condition exists.
If charging can not bring specific
gravity to that of full charge
level, battery should be replaced.
Battery may be defective or very
run down.
After the 10 secs load test ends,
note the voltage reading on the
display. Voltage recovery to
12V/6V or above within seconds
indicates defective battery. Slow
voltage recovery indicates run
down condition. For best results,
check specific gravity.