Installing Batteries - Southwire T100PK Instrucciones De Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Checking Continuity
WARNING:
Never test continuity on a live circuit.
1. Connect the test leads to the wire or device being tested.
2. Set the TONE/CONT switch to the CONT position.
3. The Continuity/Polarity LED will glow red if there is an electrical
path between the connection points. The tester indicates continuity
up to approximately 10,000 ohms. The LED will be brighter on low
resistance and less bright on high resistance.

Installing Batteries

WARNING:
To avoid electric shock, disconnect the test leads from
any source of voltage before removing the battery cover. DO NOT operate the
tester until the battery cover has been properly secured.
1. Remove the Philips screw located on the back of the
Tone Generator and Amplifier Probe.
2. Remove the battery cover.
3. Replace battery with one 9 volt battery.
4. Secure the battery cover.
Tone Generator
DO NOT USE
Battery
ON LIVE CIRCUITS
WITH TONE MODE
Cover
Philips
screw
Philips
screw
Amplifier Probe
Battery Cover
9
Replacing the Amplifier Probe Tip
1. Remove the battery cover on the Amplifier Probe.
2. Lift up the battery. Remove the spare tip stored under the battery.
3. Reseat the battery and secure the battery cover.
4. Remove the Phillips screw holding the tip in place.
5. Replace the tip.
6. Secure the tip
with the screw.
Spare Tip
stored
under
battery
REGISTER YOUR PRODUCT
Register your product purchase at www.southwiretools.com or by scanning the QR code on this
manual. At Southwire, we are dedicated to providing you with the best customer experience. By
following a few quick steps to register, you can experience quicker service, more efficient support,
and receive information on our future products. Simply provide your model number, serial number,
and just a few pieces of information about yourself – it is that quick and easy.
LIMITED WARRANTY AND LIMITATION OF LIABILITY ON SOUTHWIRE METERS & TESTERS
Southwire Company, LLC warrants this product to be free from defects in material and
workmanship for two years from the date of purchase. This warranty does not cover fuses,
disposable batteries, or damage arising from an accident, neglect, misapplication,
contamination, modification, improper maintenance or repair, operation outside of specifications,
or abnormal handling of the product. Southwire's sole liability, and the purchaser's exclusive
remedy, for any breach of this warranty is expressly limited to Southwire's repair or replacement
of the product. Whether Southwire repairs or replaces the product will be a determination that
Southwire makes at its sole discretion. SOUTHWIRE MAKES NO WARRANTY THAT THE
PRODUCT WILL BE MERCHANTABLE OR FIT FOR ANY PARTICULAR PURPOSE.
SOUTHWIRE MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, OTHER THAN THE
WARRANTY SPECIFICALLY SET FORTH HEREIN. SOUTHWIRE WILL NOT BE LIABLE FOR
ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES FOR
ANY BREACH OF THIS WARRANTY.
This warranty is void if this product is used for rental purposes. No product reseller is authorized
to extend any other warranty on Southwire's behalf relating to this product, and no such reseller
warranty will be binding on Southwire. If you have a warranty claim, or if the product needs to
be serviced during or after the warranty period set forth above, please contact the Customer
Service Department at 855-SWTOOLS (855-798-6657). The sender is responsible for all
shipping, freight, insurance, and packaging costs associated with sending a product to
Southwire. Southwire will not be responsible for lost or damaged products returned pursuant
to this warranty. All products returned to Southwire under this warranty should be mailed to:
Southwire Company, LLC
Attention: Tool Warranty Return
5810 Trade Center Court
Villa Rica, GA 30180-6701
Philips
Probe Tip
9V Battery
screw
(replaceable)
10