Descargar Imprimir esta página

Eaton LUMARK IB514011EN Instrucciones De Instalación página 2

Controlador de reemplazo crosstour maxx

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation Instructions - Crosstour MAXX Replacement Driver Options
INSTALLATION
Tools Required:
Phillips-head screwdriver, electrical wiring tools.
Driver Replacement
1.
Unscrew door with Phillips-head screwdriver. Remove
door from back box and secure door into locking hinges
located at the top of the back box. (Figure 1.)
2.
Disconnect the black and white wire on the driver and
the ground wire on the front cover.
3.
Remove front cover from fixture and place face down
on a soft surface.
4.
Snip the zip tie securing wiring to driver, disconnect red
and black wires connected to LED, and remove four
Phillips-head screws securing driver bracket. (Figure 2.)
5.
Remove old driver and bracket and replace with new
driver and bracket.
6.
Screw new driver bracket to front cover with four
supplied screws and tighten to 10 in-lbs.
7 .
Connect red wire from driver to the two red wires on
front cover. Connect black wire from driver to the two
black wires on front cover. Use zip tie to secure wiring
to top of driver.
8.
Secure door into lock hinges located at the top of the
back box (Figure 1). Reconnect the ground wire on
the front cover and the black and white wires on the
driver. Utilize Push-in connectors to make fixture-wiring
connections. (See Wiring Diagrams.)
9.
Ensure all electrical wires and connections are secured
in the back box, re-install door, and tighten door screw
to 15-20 in-lbs.
Maintenance
N
ote:
A regular maintenance schedule should be
followed to retain optimal light output and thermal
performance. Optical lens cleaning should be
performed with a clean dry cloth to remove any
dust or other contaminants. Additional lens cleaning
should be performed with non-abrasive acrylic
cleanser. Remove any dirt, leaves, or other foreign
debris from the housing and fins. Clean water may
be used to flush the fins.
2
EATON
IB514011EN
Installation instructions
Locking
Hinges
(3) Push-in
Connectors
Figure 1.
Remove
these
screws
Figure 2.
Connect all Ground Wires First

Publicidad