NATURAL GAS CONVERSION

Natural gas conversion must be performed only by your natural gas provider or
service company.
Step 1- At the control panel, disconnect the rubber gas hose from the gas valve.
Step 2- Below the burner, disconnect the aluminum gas tube from the orifice elbow.
Step 3- Remove the 2 M4 nuts from the orifice holder and remove the orifice bracket
assembly.
Step 4- Disconnect the orifice from the elbow and replace it with the Natural Gas orifice
from the kit.
Re-fit the orifice bracket assembly onto the holder using the 2 M4 bolts and nuts. Re-connect the
aluminum gas tube into the end of the elbow. Connect your Natural Gas supply line onto the gas
valve at the control panel. BEFORE ATTEMPTING TO USE THE FIREPIT, check ALL of the
connections for leaks using a solution of soapy water. If a leak is discovered and any bubbles are
NEVER USE A FLAME
seen, close the main gas valve and re-tighten ALL the connections.
TO CHECK FOR GAS LEAKS!