Warning: If these instructions are not followed exactly, a fire or
explosion may result causing property damage, personal injury
or loss of life.
1. Open the tank drawer and find the control panel on the left.
Make sure the control knob is in the "OFF" position. See
Figure 9. Open the tank valve all the way.
2. Push in the igniter button. You will hear a slight clicking sound.
With the igniter button pushed in, push and turn the control
knob to the "ON" position. The fire should light within a few
seconds. Once the flame is lit, release the igniter button and
continue to hold the control knob in for 10 to 15 seconds.
Release the control knob. The control knob should pop back
out and then the fire remains lit. Note: If the fire does not light,
turn the knob to the "OFF" position and wait five (5) minutes
before trying again.
3. To turn down the flame, push the control knob in slightly and
turn to Medium (medium flame), or Low (small flame).
4. To shut down the fire pit, turn the control knob to the "OFF"
position and turn off the tank valve.
The flames should look like those in Figure 10. To clean the burner, use a soft brush after
the burner has cooled completely. Never use a vacuum cleaner on the burner. It is
recommended to store the firepit indoors during winter if it will be subjected to freezing
temperatures. The LP cylinder must be disconnected and removed from the appliance
before the appliance can be stored indoors.