Step 5- Stick the conversion label on the rating plate as shown in Figure 7.
Serial Number _________________
CAUTION: The gas pressure regulator provided with this appliance must be used. This regulator is set for an outlet pressure of
This appliance has been converted to use Natural Gas. Input 40,000 Btu/hr.
Max Gas Supply Pressure 7 inch w.c. (1.74 kPa) Min. Gas Supply Pressure 5 inch w.c. (1.24 kPa)
Minimum clearance from combustible constructions: Sides: 60.9 cm/24 inches. Top 182.8 cm/72 inches.
FOR OUTDOOR USE ONLY. If stored indoors, detach and leave cylinder outdoors.
Make sure the control knob is in the "OFF" position.
Unscrew the push button cap on the ignition module
located on the control panel to access the battery
compartment. The ignition module requires one Alkaline
AAA size battery (1.5V). The negative (-) end goes in first.
See Figure 8. Dispose of battery safely. Battery may
explode or leak if charged or disposed of in fire. Make
sure of the polarity. The battery included is mercury and
cadmium free.
CAUTIONS: BATTERY INSTRUCTIONS
●Always purchase the correct size and grade of battery most suitable for the intended
use.
●Always replace the whole set of batteries at one time, taking care not to mix old and
new ones, or batteries of different types.
●Clean the battery contacts and also those of the device prior to battery installation.
●Ensure the batteries are installed correctly with regard to polarity (+ and -).
●Remove batteries from equipment which is not to be used for an extended period of
time.
●Remove used batteries promptly.
For recycling and disposal of batteries to protect the environment, please check the
internet or your local phone directory for local recycling centers and / or follow local
government regulations.
Metal Rating Plate
Figure 7
BATTERIES
Model Number: 98900
9
Conversion Label
IGNITION
MODULE
Figure 8