Pressure switch refit procedure
Warning! The following steps must be performed by qualified personnel.
When the pressure switch light, near main switch in ON, this indicates that the pressure switch
intervened to deactivate the compressor. In order to refit this device, it is important to follow the
instructions below:
1°
Disconnect the power cable;
2° Press the pressure switch button under the frame of the machine.
In order to avoid this situation to happen again, verify the correct position of the machine as in the
pic.5 pag.87 and/or clean the condenser as described at pag.21.
Spia Pressostato
Pressure switch light