GOLD MULTI 200.2 / 200.4 XL / 201.4
MIG MANUAL - FIG III
• Selecting MIG manual mode
• Wire speed adjustment
• Arc voltage adjustment
• Setting management torch in SPOT and
DELAY mode
MIG SYNERGIC - FIG III
• Selecting MIG Synergic mode
• Selecting the type of wire
• Selecting the wire diameter
Selecting the metal thickness to weld
Keep button 2 pushed and at the same
time turn the upper knob until the display
shows MIG Manual. Release button 2 to
validate this selection
Turn the upper knob to adjust the wire
speed.
Turn the lower knob to adjust the arc
voltage.
• Keep button 3 pushed to select normal
mode.
• Keep pressing button 3 and at the same
time turn the upper knob to select SPOT
mode and to configure it. Adjustable
between 0.5 to 5 sec.
In the same way turn the lower knob to
configure the DELAY mode. Adjustable
between 0 to 5 sec."
Keep button 2 pressed and at the same
time turn the upper knob until "MIG
Synergic" is displayed.
Keep button 2 pushed and at the same
time press the lower knob to go to the
wire type selection menu. Select the wire
type with the upper knob.
Keep the button 2 pushed and at the
same time press the lower knob to go to
the wire diameter selection menu.
Select the diameter with the upper knob.
Then release the button 2 to validate.
Turn the upper knob to select the metal
thickness to weld.