10-556 / 10-560 / 10-586
4. PROGRAMMING
Programming the bell push-button
* Programming of the bell push-buttons is described in detail in the manual of the system power supply (10-801, 10-802 or 10-806) or of the service unit
(10-870).
• *If you use the service unit, tear off the serial number to be found on the rear side of the video internal unit or the packaging box and stick it on the installation
diagram.
* Only 1 device of this type can be programmed per memory location. Master-slave programming is not possible. See technical catalogue for the number of
memory locations per bell push-button (1 or 2 ) of the external unit.
This manual describes the surface mounting of the monitor.
Open door.
Operates relay which is connected to terminal K.
Activate control function 8 to operate a programmable relay (10-830, 10-836 or 10-837).
Switch light relay on the power supply.
View the camera image from one or more cameras when no communication is taking place.
Het camerabeeld van één of meerdere camera's oproepen, wanneer er geen communicatie is.
Activate control function 12 to operate a programmable relay (10-830, 10-836 or 10-837).
Briefly press the button to accept the call. Press the button to speak, release the button to listen (walkie-talkie principle). The call automatically ends
after 40 seconds, if the button is no longer pressed down. The call also automatically ends 4 seconds after operating the door lock.
Alternative functions
A number of function keys can also be assigned the following alternative functions:
• If no call has been initiated: switch on the light.
• If a call has been initiated, this key retains its standard function, i.e. opening the door.
• Open floor door via control function 11. See chapter 'Activating floor bell push-button'.
Either parallel operation of the video internal unit based on the master/slave principle*
Or
making an internal call
Or
activating control function 10
Either activating ring-and-come in function (green LED lights up)
Or
activating reroute function
Or
making an internal call
Either making an internal call
Or
activating control function 9
* on most external units up to 2 internal units can be programmed per bell push-button. If only 1 internal unit is used or if you want to program more internal
units on a bell push-button, this must be done according to he master/slave principle. The internal unit that is programmed as SLAVE on a MASTER will always
follow all actions of the MASTER
For more information on programming via the power supply, see manual of the power supply.
For more information on programming via the service unit, see manual of the service unit (10-870).
Opening floor door with the door opener key
You can also program the function open floor door on the
➥ 1
Press
for 8s until you hear a beep and both LEDs light up.
➥ 2
Press
for 8s until you hear a beep and both LEDs go out.
➥ 3
Wait 8s until you hear a beep and the LEDs go out.
The function open floor door is now programmed on the
You can then activate control function 11 with the
programmable relay (10-830, 10-836 or 10-837).
Setting the ringing tone
You can set a different ringing tone for each type of call via the function key buttons. You can choose from 13 ringing tones.
➥ 1
for 8s until you hear a beep and both LEDs light up.
Press
➥ 2
Repeatedly press one of the following function key buttons to go through the different ringing tones.
• Press
to select the ringing tone for the external unit with an address equal to 0.
to select the ringing tone for the external unit with an address different from 0.
• Press
28
function key:
function key.
key to open the floor door up to 30s after a floor call. Control function 11 can be programmed on a
via the power supply or the service
unit
Via the service unit
Via the service unit
Via the service unit