4
Installation
Mechanical
• Handle the MPPES-... with care so that the electrical connection
is not damaged.
Such damage will reduce
operational reliability
• Make sure there is sufficient space for the cable connection and
tube couplings.
In this way you will prevent the connecting cable from being
bent.
• Place the MPPES-... as close to the cylinder as possible.
This results in better control precision and shorter re-
sponse times.
• Insert the screws for mounting into the two holes 5.
• Secure the MPPES-... at the intended position.
4.1
Pneumatic
• Remove the covers from the compressed air supply ports.
• Attach the pneumatic tubing to the following connections:
– Compressed air supply port 1
– Air supply port 2
• Screw a silencer (
4.1.1
Electrical
• Note the rating plate.
A distinction is made between the following valve variants (
Designation on the rating plate
Designation
Electrical setpoint value
Tab. 13
Festo – MPPES – 1304d English
Accessories) into the exhaust port 3.
Fig. 5
Fig. 6
Tab. 13).
MPPES-...-010
Voltage variant
DC 0 ... 10 V
MPPES-...-420
Current variant
4 ... 20 mA
17