Installation
EWS 100
With the multiple inlet adapter, up to 3 condensate lines can be connected directly to the EWS unit.
The inlet adapter can be mounted on the wall. It has three ½" hose connectors for infl ow from the Q
MAT and one 1" hose connector for the hose to the EWS.
The ½" connector on the EWS must not be removed.
The 1" hose can be pulled over the ½" connector. (See below.)
Up to 4 EWS units can be joined to a fl ow splitter.
If there are more than 4 feed points, it will be necessary to install a header of 1" diameter above
EWS inlet (height 24" above fl oor) with a slight slope down to the EWS unit (min. 1°)
• Feed in the condensate from the top.
ø0.26"
(ø6,5)
½"(DN13)
1" (DN25)
D
½"
O NOT REMOVE
CONNECTOR

Wastewater Drain

• Must be lower than the water outlet of the EWS
• Install a trap against odors
Connecting the wastewater hose:
• Use the hose supplied and attach it to the EWS water outlet.
• Lay the hose with a continuous slope down to the wastewater drain (trap).
8
1.77"
(45)
½"(DN13)
M
I
A
1" (DN25)
Quincy Compressor-EWS Emulsion Separator
ULTIPLE
NLET
DAPTER
C
L
OLLECTING
INE
1" (DN25)
F
S
LOW
PLITTER
½"(DN13)