Lamp hot
HEAT
Lamp error
LA.Er
CONTROL BOARD OPERATION:
1. Select working mode by pressing MODE.
2. Press ENTER to confirm the selection.
3. Press UP and DOWN to select working condition.
4. Press ENTER to confirm the selection.
7. Cleaning and Maintenance
1. All screws should be tightened and free of corrosion.
2. The housing, the lenses, the mounting supports and the installation location (e.g. ceiling, suspension, trussing)
should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting supports, do not
change the location of the connections ...
3. Mechanically moving parts must not show any signs of wear and tear.
4. The electric power supply cables must not show any damage. Have a qualified technician maintain the device.
5. Disconnect the device from the mains prior to maintenance activities.
6. Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
7. There are no user-serviceable parts, apart from the lamp and the fuse (see "Installation").
8. Contact your dealer for spare parts if necessary.
8. Technical Specifications
Optical system
Power Supply
Power Consumption
DMX channels
Colour temp.
Luminance
Lamp
Fuse
Dimensions
Total Weight
Max. Ambient Temperature
Max. Housing Temperature
The information in this manual is subject to change without prior notice.
VDP575MHW16
High luminous efficiency parabolic reflector.
Zoom 7° - 28°
200mm diameter Fresnel lens
All lenses are anti-reflection coated.
max. 230VAC / 50Hz
max. 850W
16 channels
7000K
49000 Lux
1 x LAMP575MSR/2SYL)
T6.3A, 230VAC
379 x 428 x 476mm
36.5kg
45°C
80°C
6
HQ POWER