Circuit Breaker - Lincoln B Serie Manual Del Usario

Ocultar thumbs Ver también para B Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Model 1400, 1440, 1442, 1442E, 1444, 1444E
PowerLuber Grease Gun
1230
30 Inch Hose
5852
Coupler

Circuit Breaker

To prevent motor from overload circuit beaker
will stop the motor when operating pressure
exceeds 7,000 PSIG (476 bar). Manual
press-to-reset red color button will pop up,
see Fig 1. To reset push the red button after
waiting for 5 to 10 seconds.
The circuit breaker also is an indication of the
bearing or lubrication line conditions. If the
red button is popping out this is an indication
of clogged or tight bearing, clogged grease
fitting or blocked lubrication line. Correct this
before resetting and continue lubrication with
PowerLuber.
Changing "L" or "H" Mode
To prevent damage to the transmission
gears, stop the motor running before
changing the "L" or "H" mode.
© Indicates change
Page Number - 4
Vent/Bulk
Fill Valve
Figure 1©
Circuit Breaker
Manual Reset Button
High/Low
Output Lever
Stroke
Counter
1400
1401
Battery
To change the mode of operation:
"L" (low output/high pressure)
"H" (high output/low pressure)
When motor is not running, push the red lever
(Fig. 1) until letter "L" or "H" will be completely
visible in the window.
In case the red lever is not completely shift-
ed/engaged, hold this lever and start the tool.
High output is recommended if the tool is used
to lubricate large bearings not requiring high
pressure, beyond 3,000 PSIG (204 bar). Also,
high output is recommended if tool is used to
refill small reservoirs of the automatic lubrication
systems.
Low output is recommended if the tool is used
in construction, mining applications and general
lubrication. Low output will provide the maximum
pressure of up to 7,000 PSIG (476 bar) the tool
is capable of producing.
Form 402103

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

1400144014421442e14441444e ... Mostrar todo

Tabla de contenido