Test of the safety edges
This menu allows setting the method of control of the safety edges
working.
no
Test disabled
Foto
Test enabled for optical safety edges
rESi
Test enabled for conductive rubber safety edges
W.L.
Wireless edge system test enabled
WARNING: V2 suggests to keep activated the test of the
photocells in order to grant a higher safety of the system.
End of Stroke Inputs
PD18 control unit allows connecting magnetic limit switch which are
activated by the door motion and showing to the control unit that each
door reached its position of complete opening or closing.
Si
end of stroke inputs are enabled
no
end of stroke inputs are disabled
Encoder Input
The PD18 control unit allows connection of the encoder indicating
the position of the gate to the control unit.
Si
encoder input enabled
no
encoder input not enabled
Encoder sensitivity
This menu allows the sensitivity of the rate sensor to be adjusted.
A decreased rate below the set threshold indicates the presence of an
obstacle.
If set to 0 the obstacle is only detected when the gate is stopped.
For sensor operation, please refer to the dedicated section "OBSTACLE
SENSOR" (page 40)
Anti-skid
When an opening or closing operation is interrupted by a command or
for the intervention of the photocell, the set-up time for the opposite
movement would be excessive, so the control unit operates the motors
only for the time necessary to recover the actually covered journey. This
could be not sufficient, particularly in the case of very heavy gates, as
because of the inertia at the inversion moment the gate runs an extra
space in the previous direction that the control unit is not able to take
into account.
If after an inversion the gate does not return exactly to the starting
position, it is possible to set an anti-skid time that is added to the time
calculated by the control unit in order to recover the inertia.
WARNING: if the function ASM is disabled, the reverse
manoeuvre lasts until the gate reaches the limit switch.