Technical Data; Proper Use - Matrix PG 2200-4 Traducción Del Manual Original

Generador de corriente
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 18
level include the properties of the work area,
other sound sources etc., the number of machines
and other processes in the vicinity, as well as the
time span in which the operator is subjected to
the noise. Also, the permitted immission level can
vary from country to country. Nevertheless, with
this information the user is able to make a better
assessment of the dangers and risks involved.
- Never use faulty or damaged electrical
equipment (this also applies to extension cables
and plug connections).
CAUTION!
Read all safety regulations and instructions.
Any errors made in following the safety
regulations and instructions may result in an
electric shock, fire and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.

3. Proper use

The device is designed for applications operated
with a 230 V alternating current source alternating
current source .
Be sure to observe the restrictions in the safety
instructions. The generator is intended to
provide electric tools and light sources with
electricity. When using the device with household
appliances, please check their suitability in
accordance with the relevant manufacturer's
instructions. In case of doubt, ask an authorized
dealer of the respective appliance. The machine
is to be used only for its prescribed purpose. Any
other use is deemed to be a case of misuse. The
user / operator and not the manufacturer will
be liable for any damage or injuries of any kind
caused as a result of this.
28

4. Technical data

Generator type:
Protection type:
Continuous rated power Prated (S1):
Rated voltage Urated:
Rated current Irated:
Frequency Frated:
Drive engine design:
Single-cylinder forced air-cooled 4-stroke OHV
Displacement:
Fuel type:
Tank capacity:
Engine oil:
Appox.0.6 l (15W40/<0
Consumption at 2/3 load:
Weight:
Guaranteed sound power level L
Power factor cos φ:
Power class:
Max. temperature:
Max. altitude (above mean sea level):
Spark plug:
Synchronous
IP 23M
2.0 kW
2 * 230 V ~
8.7 A
50 Hz
196 cm
Normal unleaded petrol
o
C: 5W30)
528g/h
42 kg
:
95 dB(A)
WA
40 °C
1000 m
LG F6TC
3
15 l
1
G1

Publicidad