- Never operate the generator in rain or snow.
- Never touch the generator with wet hands.
- Guard against electric danger. When working
outdoors, use only extension cables that are
approved for outdoor use and which are marked
accordingly (H07RN..).
- The overall length of the extension cables used
may not exceed 50 m for 1.5 mm
2
2.5 mm
.
- No changes may be made to the settings of the
motor or generator.
- Repairs and adjustment work may only be
carried out by authorized trained personnel.
- Do not refuel or empty the tank near open
lights, fire or sparks. Do not smoke!
- Do not touch any mechanically driven or hot
parts. Do not remove the safety guards.
- Do not expose the tools to damp or dust.
Permissible ambient temperature – 10 to + 40°C,
max. altitude above sea level 1000 m, relative
humidity: 90 % (non-condensing)
- The generator is driven by a combustion engine,
which produces heat in the area of the exhaust (on
the opposite side of the sockets) and the exhaust
outlet. You should therefore keep clear of these
surfaces because of risk of skin burns.
- The values quoted in the technical data for
sound power level (LWA) and sound pressure level
(LWM) are emission values and not necessarily
reliable workplace values. As there is a correlation
between emission and immission levels, the
values are not a reliable basis for deciding on any
additional precautions which may be needed.
Factors influencing the actual user immission
level include the properties of the work area,
other sound sources etc., the number of machines
and other processes in the vicinity, as well as the
time span in which the operator is subjected to
the noise. Also, the permitted immission level can
vary from country to country. Nevertheless, with
this information the user is able to make a better
assessment of the dangers and risks involved.
- Never use faulty or damaged electrical
equipment (this also applies to extension cables
and plug connections).
Read all safety regulations and instructions.
Any errors made in following the safety
2
and 100 m for
regulations and instructions may result in an
electric shock, fire and/or serious injury.
Keep all safety regulations and instructions in a
safe place for future use.
3. Proper use
The device is designed for applications operated
with a 230 V alternating current source for 230 V
and 400 V alternating current source.
Be sure to observe the restrictions in the safety
instructions. The generator is intended to
provide electric tools and light sources with
electricity. When using the device with household
appliances, please check their suitability in
accordance with the relevant manufacturer's
instructions. In case of doubt, ask an authorized
dealer of the respective appliance. The machine
is to be used only for its prescribed purpose. Any
other use is deemed to be a case of misuse. The
user / operator and not the manufacturer will
be liable for any damage or injuries of any kind
caused as a result of this.
4. Technical data
Generator type:
Protection type:
Continuous rated power Prated (S1):
Maximum power Pmax:
Rated voltage Urated:
Frequency Frated:
Drive engine design:
Single-cylinder forced air-cooled 4-stroke OHV
Displacement:
Fuel type:
68
CAUTION!
3 kW (230V~)/5 kW (400V 3~)
3.3 kW (230V~)/5.5 kW (400V 3~)
Normal unleaded petrol
Synchronous
IP 23M
2* 230 V~
1X400V 3~
50 Hz
3
458 cm