INTRODUCTION
EN
This instruction sheet provides you with the information required to safely own
and operate your product. Retain these instructions for future reference.
The product you have purchased is of the highest quality workmanship and
material, and has been engineered to give you long and reliable service. This
product has been carefully tested, inspected, and packaged to ensure safe
delivery and operation. Please examine your item(s) carefully to ensure that no
damage occurred during shipment. If damage has occurred, please contact the
place of purchase. They will assist you in replacement or repair, if required.
READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING
TO INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. KNOW THE
PRODUCT'S APPLICATION, LIMITATIONS, AND POTENTIAL HAZARDS.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION. FAILURE TO COMPLY WITH THESE INSTRUCTIONS
COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
DESCRIPTION
Little Giant Submersible 20S Series Sewage Ejector Pumps and 20E Series
Effluent Pumps are recommended for use in basins or lift stations and suitable
for pumping sewage, effluent, wastewater and other non-explosive, non-cor-
rosive liquids. The 20S Series Sewage Ejector Pumps have 2" spherical solids
handling capability. The 20E Series Effluent Pumps have 3/4" spherical solids
handling capability.
Little Giant offers a complete line of control systems, along with a complete line
of alarms, basins, covers, and check valves.
SPECIFICATIONS
Discharge Size:
20E and 20S — 2" or 3"
Handling Capabilities: E Series — 3/4" spherical solids
S Series — 2" spherical solids
Pump Housing:
Cast iron
Volute:
Cast iron
Impeller:
Non-clog brass with pressure relief vanes
Motor:
3 Phase, 3200 RPM (control panel required)
Hardware:
300 Series stainless steel
Bearing:
Ball
Shaft Seal:
Mechanical, spring loaded, rotating carbon with Nitrile
boot and stationary ceramic seat, with secondary Nitrile
exclusion seal
Power Cord:
14 AWG 4-conductor, copper, stranded
Cooling:
The motor housing contains a cooling oil to provide
cooling for the motor and to lubricate bearings and
seals. These pumps are capable of operating with the
motor housing partially exposed for extended periods
of time, providing sufficient motor cooling and bearing
lubrication. However, for the best cooling and longest
motor life, the liquid level being pumped should normally
be above the top of the cast iron motor housing.
SAFETY GUIDELINES
WARNING: RISK OF ELECTRIC SHOCK. THIS PUMP IS SUPPLIED WITH A
GROUNDING CONDUCTOR. TO REDUCE THE RISK OF ELECTRIC SHOCK,
BE CERTAIN THAT IT IS CONNECTED TO A PROPER ELECTRICAL GROUND.
DO NOT REMOVE CORD OR STRAIN RELIEF. DO NOT CONNECT CONDUIT
TO PUMP. THIS PUMP MUST BE INSTALLED BY QUALIFIED PERSONNEL.
MODEL
CATALOG
NO.
NO.
HP
20E-CIM
520225
2
20E-CIM
520250
2
20E-CIM
520275
2
20S-CIM
520125
2
20S-CIM
520150
2
20S-CIM
520175
2
20E-CIM
20S-CIM
3 Phase
PH
VOLTS
HZ
AMPS
3
200-208
60
13.1
3
230
60
11.6
3
460
60
5.7
3
200-208
60
14.5
3
230
60
12.6
3
460
60
6.1
1. Read all instructions and Safety Guidelines thoroughly. Failure to follow
the guidelines and instructions could result in serious bodily injury and/or
property damage.
2. DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH
AS GASOLINE, FUEL OIL, KEROSENE, ETC. FAILURE TO FOLLOW THIS
WARNING CAN RESULT IN PERSONAL INJURY AND/OR PROPERTY
DAMAGE.
3. During normal operation the pump is immersed in water. Also, during rain
storms, water may be present in the surrounding area of the pump. Caution
must be used to prevent bodily injury when working near the pump.
4. Do not run the pump in a dry basin. If the pump is run in a dry basin, the
surface temperature of the pump will rise to a high level. This high level
could cause skin burns if the pump is touched and will cause serious damage
to your pump.
5. Do not oil the motor. The pump housing is sealed. A high grade dielectric
oil devoid of water has been put into the motor housing at the factory. Use
of other oil could cause serious electric shock and/or permanent damage
to the pump.
6. Do not install in locations classified as hazardous in accordance with the
National Electrical Code, ANSI/NFPA 70.
7. When a pump is in a basin, etc., do not touch motor, pipes or water until
unit is unplugged or shut off. If your installation has water or moisture present,
do not touch wet area until all power has been turned off. If shut-off box is
not accessible, call the electric company to shut off service to the house, or
call your local fire department for instructions. Failure to follow this warning
can result in fatal electrical shock.
8. The flexible PVC-jacketed cord assembly mounted to the pump must not
be modified in any way, with the exception of shortening the cord to fit into a
control panel. Any splice between the pump and the control panel must be
made within a junction box and mounted outside of the basin, and comply with
the National Electrical Code. Do not use the power cord for lifting the pump.
This pump must be used with a control panel which incorporates thermal or
overload protection and stalled-rotor conditions and shall be rated or set to a
maximum ampere rating as noted below.
Figure 1
GPM @ HEAD
10'
20'
30'
40'
N/R
135
125
110
N/R
135
125
110
N/R
135
125
110
205
168
140
115
205
168
140
115
205
168
140
115
INSTALLATION
SHUT
60'
80'
100'
OFF (Ft.)
89
62
19
110
89
62
19
110
89
62
19
110
72
77
72
77
72
77
POWER
WEIGHT
CORD (ft.)
(lbs.)
20
85
20
85
20
85
20
85
20
85
20
85
1

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Franklin Electric Little GIANT 20S Serie

  • Página 1 2. DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH 20S-CIM Franklin Electric Co., Inc. AS GASOLINE, FUEL OIL, KEROSENE, ETC. FAILURE TO FOLLOW THIS P. O. Box 12010 WARNING CAN RESULT IN PERSONAL INJURY AND/OR PROPERTY Oklahoma City, OK 73157-2010 405.947.2511 •...
  • Página 2: Cleaning Impeller And Volute

    Figure 2 Figure 3 Union Raccord Gate Valve Unión Clapet de la vanne Check valve Vent To Control Panel Válvula de la compuerta Clapet de retenue Aération Verifique válvula Respiradero Discharge Pipe Tuyau de sortie Tubería de descarga Intake Entrée Entrada Caulking Hub Collet d’étanchéitéOrifice de prise d’air...
  • Página 3 l’eau autour de la pompe. C’est pourquoi il faut faire attention si on travaille INTRODUCTION près de celle-ci. 4. Ne pas faire fonctionner la pompe dans un puisard à sec. Une température Cette feuille d’instructions vous fournit les informations nécessaires pour entre- élevée à...
  • Página 4: Introducción

    Les installations de fosse septique et d’effluent nécessitent un évent de puisard Cojinete: Bola indépendant. Le dessus ou le couvercle du puisard est pourvu d’un orifice de Sello del eje branchement qui doit être raccordé à l’aération existante de l’édifice ou s’ouvrir de la bomba: Carbón de rotación mecánico accionado por resorte à...
  • Página 5: Mantenimiento Y Servicio

    La bomba funcionará continuamente si se conectarse directamente a un toma- Código Eléctrico Nacional (NEC) más reciente. corriente. Debe tomarse las precauciones para evitar que la bomba funcione Para ajustarse a las disposiciones del Código Eléctrico Nacional, todas las con un sumidero seco. bombas deben tener cables 14 AWG o mayores.
  • Página 6 TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM • FONCTIONNEMENT DÉFECTEUX • PROBABLE CAUSES • CAUSES PROBABLES CORRECTIVE ACTION • SOLUTIONS PROBLEMA • CAUSAS PROBABLES • SOLUCION Pump not plugged in. • La pompe n’est pas branchée. • La bomba no Plug in pump.
  • Página 7: Warranty Period

    LITTLE GIANT PUMP COMPANY, subsidiary ou des bassins de transfert. Elles conviennent également pour le pompage of FRANKLIN ELECTRIC COMPANY, INC., will repair or replace to the original des eaux d’égout, de l’effluent, des eaux usées ou d’autres liquides qui ne user or consumer any portion of your new LITTLE GIANT product which proves sont ni explosifs, ni corrosifs et ni abrasifs, dont la température ne dépasse...
  • Página 8: Garantia Limitada Sumidero, Efluentesy Aguas Residuales Residenciales

    ..... . .1-888-572-9933 Para la ayuda técnica, por favor póngase en contacto ..1-888-956-0000 www.LittleGiantPump.com CustomerService-WTS@fele.com Form 994672 - 10/02/2009 © 2009 Franklin Electric Co., Inc. Little Giant® is a registered trademark of Franklin Electric Co., Inc.

Este manual también es adecuado para:

Little giant 20e serieLittle giant 20e-cimLittle giant 20s-cim

Tabla de contenido