PARKSIDE PDM 300 C2
3. Technical specifications
Display
Measurement rate
Measurement cable length
Battery type
Overvoltage category
Hold function
Automatic polarity display
Low battery display
Auto power OFF function
Operating temperature, humidity
Storage temperature, humidity
Dimensions (W x H x D)
Weight
The technical data and design may be changed without prior notice.
Direct current
Area
200 mV
2 V
20 V
200 V
300 V
Input impedance: 10 MΩ
Overload protection: 300 V DC/AC RMS
Alternating current
Area
2 V
20 V
200 V
300 V
Input impedance: 10 MΩ
Frequency range: 40 Hz to 400 Hz
Overload protection: 300 V AC RMS
Display: Root mean square value (RMS of sine wave)
52 - English
3 ½ digit LC display, max. display: 1999
approx. 2 to 3 measurements/second
approx. 80 cm each
9 V block battery
CAT III 300 V (digital multimeter and measurement cables)
yes
yes
yes
yes
0 °C to +40 °C, max. 75 % rel. humidity
-10 °C to +50°C, max. 85 % rel. humidity
80 x 166 x 36.5 mm (inc. range selector switch)
approx. 190 g (without battery or measurement cables)
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Precision
± (0.5 % + 5)
Precision
± (1.0 % + 5)