Resistance Measurement; Continuity Testing; Diode Test - Parkside PDM 300 C2 Manual De Instrucciones E Indicaciones De Seguridad

Multimetro autorrango digital
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

7.6 Resistance measurement

CAUTION! Make sure that all circuit components, circuits and parts to be measured are
disconnected and discharged. Otherwise the multimeter could get damaged.
• Connect the black measurement cable to the COM connection [4] and the red measurement cable
to the
OUT INPUT connection [5].
• Set the range selector switch [3] to the Ω position.
• Connect the measurement probes [6] to the object to be measured.
• The measured reading is now shown on the display [1].
For resistances > 1MΩ, the measurement may take a few seconds. In this case, wait until the
reading has stabilised.
For measurements of lower resistances (200 Ω range), the resistance of the device's own
measurement cables can distort the reading. In order to avoid this, note down the reading for the
measurement with the measurement probes short-circuited, and subtract this from the actual
measurement reading.

7.7 Continuity testing

CAUTION! Make sure that all circuit components, circuits and parts to be measured are
disconnected and discharged. Otherwise the multimeter could get damaged.
• Connect the black measurement cable to the COM connection [4] and the red measurement cable
to the
OUT INPUT connection [5].
• Set the range selector switch [3] to the
• Connect the measurement probes [6] to the object to be measured.
• If the resistance is under about 30 Ω, the buzzer sounds and the measured reading is shown on the
display [1].

7.8 Diode test

CAUTION! Make sure that all circuit components, circuits and parts to be measured are
disconnected and discharged. Otherwise the multimeter could get damaged.
• Connect the black measurement cable to the COM connection [4] and the red measurement cable
to the
OUT INPUT connection [5].
• Set the range selector switch [3] to the
• Connect the red measurement probe [6] to the anode of the diode to be tested and the black
measurement probe [6] to the cathode.
• The threshold voltage is shown in volts on the display [1]. If the display [1] shows "OL", the diode is
being measured in the wrong direction or it is faulty. Carry out a measurement in the opposite
direction to check.