Check that the charging level exceeds 12.6V in the 12V position or 25.2V in the 24V position.
Connect the 12V – 24V selection plug to the 0V position.
For all Boosters, 12V, 24V and 12V-24V :
- Check the power switch is set to
- Check that the booster is secured and will not move.
- Connect the red « positive terminal » clamp to the positive terminal on the vehicle.
- Connect the black « negative terminal » clamp to the negative terminal on the vehicle.
- If the alarm buzzes, this means that polarities were reversed.
- Switch the power switch to
- On the B124.1, set the selector to the 12V position for 12V vehicles or 24V for 24V vehicles.
- Do not await! Start immediately the vehicle. Never activate the starter for more than 8 seconds consecutively. Wait
for two minutes between each starting attempt.
- Immediately once the vehicle's engine is running, disconnect the BOOSTER starting with the negative terminal
(black clamp). Then disconnect the positive terminal (red clamp).
- Return the clamps to their holders with cables wound.
- Switch the power switch to
- Charge the booster as soon as possible.
6/ USING THE BOOSTER WITH THEE « CIGAR LIGHTER » CABLE:
For 12 Volt Boosters (models B12.1A and B12.2A):
Connect the BOOSTER to a vehicle by means of the cigar lighter cable to:
- Top up the BOOSTER's charge between two uses. This charging mode does not replace continuous charging using the charger
supplied with your FACOM booster.
- Supply a vehicle via an accessory connector.
BEFORE PROCEEDING, CHECK THE VEHICLE IS COMPATIBLE WITH THIS USE.
DO NOT CONNECT A 12 VOLT VEHICLE TO A 24 VOLT BOOSTER THROUGH A « CIGAR LIGHTER » CONNECTOR.
DO NOT CONNECT A 24 VOLT BOOSTER TO A 12 VOLT VEHICLE THROUGH A « CIGAR LIGHTER » CONNECTOR.
7/ PROTECTION FUSES
All FACOM BOOSTERS are fitted with a 20A thermal fuse protecting only the BOOSTER charging circuit.
For 12 Volt boosters (models B12.1A and B12.2A):
• The 20A thermal fuse is a protection when using the « cigar lighter » cable. When the fuse trips, just press the red
« FUSE » button to restore the circuit.
For 24 Volt boosters (B24.1 and B24.2) and booster 12V-24V (B124.1) :
• The B24.1 and B24.2 BOOSTERS are fitted with a 500A fuse protecting the booster (not the vehicle) in case of improper
use, such as a short-circuit, a polarity reversion, or a strong overcharge.
• FACOM B24.1 and B24.2 BOOSTERS are fitted with two identical fuses. The fuse on the right-hand side, i.e. negative
terminal side (black cable and clamp) of the BOOSTER is the operating fuse.
• The fuse on the left-hand side, i.e. positive terminal side (red cable and clamp) is a spare fuse.
• If following improper use the fuse was tripped, the service fuse must be replaced with the spare fuse.
• Always use FACOM fuses reference B24-F500.
8/ SPARE PARTS
B24-F500 : Fuse for 24 Volt BOOSTER and booster 12V-24V
B12: cigar lighter cable ➔ for 12 Volt BOOSTER only.
B12-1ACH: Charger for BC12.1A
B12-2ACH: Charger for BC12.2A
B24-1CH: Charger for BC24.1, BC24.2 and B124.1
.
OFF
ON.
(B12.1A, B12.2A, B24.1, B24.2)
OFF.