14. Use of megaohmeter

Megging of an installation incorporating the
frequency converter is not allowed, because the
electronics may be damaged. If megging is
necessary, disconnect the frequency converter
and use the megaohmeter directly on the terminal
box of the pump.
15. Maintenance
Inspect the tank pre-loaded pressure
of the delivery vessel periodically.
16. Accessories
16.1. RA 100
Control panel for remote alarm.
Dimensions: 110x150x70
Power supply: 220-230 V single-phase
Signals all pump assembly malfunctions detected:
- No water intake.
- Assembly malfunction.
- Converter failure.
5-Watt flashing red light plus 75 dB - 3600 Hz
acoustic alarm, for use in areas of loud noise,
positioned in such a way as to be visible from a
distance.
The control panel is fitted to an energized panel
led and an alarm reset pushbutton.
RA 100
16.2. Pipe housings kit
Pipe housings for G1, G1 1/4 and G1 1/2 pipes.
For the G1 1/2 version of the EASYMAT it is
required change the screws assembled on the
heatsink with the screws provided with the G1 1/2
pipe housing kit.
16.3. Unions kit
Steel pipe with unions and pressure transducer
arrangement.
17. Disposal
European Directive 2012/19/EU (WEEE)
Observe the local regulations and dispose of any
control gear accordingly. This product contains
electrical and electronic components and should be
disposed of accordingly.