OPERATION
Before performing a leak test, be sure that no sparks can occur and you are in a spacious outdoor
area. Connect the propane gas tank to the regulator and turn the valve on the unit to the "off"
position. Brush a soap and water mixture on all connections. Turn the gas supply on; if bubbles
occur on any connection there may be a leak. If you smell gas or a leak is discovered turn the
gas valve off, disconnect propane gas tank and do not use the appliance until the leak is
repaired.
Do not use the heating unit without inspecting the gas hose. If there are signs of wear or abrasion
you must replace the hose (if applicable). Pumice stones/lava rocks/LavaGlass
strike somebody'
20 minutes after igniting. Flame height should be a yellow/blue color between 5.1 - 25.4 cm /
2 - 10 inches in height.
heating item.
To Light
1. Turn ignition control knob (N) to the "OFF" position. Connect propane gas tank to regulator
and open the cylinder valve.
2. Push the ignition control knob (N) in and turn counterclockwise to the "HIGH" position; this
will ignite the fuel.
3. If ignition does NOT take place within seconds, push and turn the ignition control knob
(N) clockwise to "OFF". Wait 5 minutes, then repeat the lighting procedure as above.
4.
To Extinguish
1. Push and turn the ignition control knob (N) clockwise to the "OFF" position.
2. Turn the propane gas tank valve on the gas tank to close the gas supply and disconnect
the propane gas tank.
WARNING
Fire product and propane gas cylinder minimum
distance must be over 152.4 cm / 60 in (as per
right side photo).
N) either clockwise or counterclockwise
could pop up and
®
152.4 cm
60 in
1-866-771-2663 | Page 9