Electrical connection
The electrical safety of this appliance is only ensured if it
·
is correctly earthed in compliance with electrical safety
standards. The manufacturer can under on circumstances
be held liable for any damages due to improper earthing.
Before connecting the appliance, check that the
technical characteristics indicated on the information plate
correspond to the electrical installation (diameter of wires,
protection devices), which must be able to accommodate
the appliance's maximum power level.
Important
Before any repair operation, remember to disconnect
the appliance.
You can connect the hob to the electrical system in two
ways:
Using an electrical outlet – use a power plug that is
·
certified for the country where the hob is being installed.
The plug must be accessible. Do not use adapters, multi-
plugs or extension leads.
Using a connection panel – if the appliance is connected
·
permanently, it must be equipped with an all-pole circuit-
breaker, in an accessible position, with a minimum gap
between contacts of at least 3mm.
Connections KTI
FR-AT-BE-DE-GP-ES-IE-IL-IS-IT-L-
5
4
3
2
1
N
L
5
4
3
2
1
L2
L1
FR-BE-CH-DE-AT-ES-IL-IT-NZ-PT--
5
4
3
2
1
N
L2
L1
5
4
3
2
1
L3
L2
L1
5
4
3
2
1
N2
N1
L2
L1
5
4
3
2
1
N
L
* Application of the simultaneity coefficient in
compliance with standard EN 335-2-6
Maximum Electrical Input:
KTI 6114 - 6014
KTI 6004
KTI 6003

Technical specifications

Voltage
Fuses
Frequency
Diameter
20 A
U-RE-FI-GB-GR-PT-SE-MA-NZ
25 A (KTI 6003)
2,5 mm²
230V-1+N~50 Hz
FR-BE-NO
20 A
25 A (KTI 6003)
230V-2~50 Hz
2,5 mm²
MA-LU-SE-IS-DK
16 A
1,5 mm²
400V2-N~50 Hz
FR-BE-NO
16 A
1,5 mm²
230V3~50 Hz
NL
16 A
1,5 mm²
230V2+2-N~50 Hz
CY-AU-NZ-KW
20 A
25 A (KTI 6003)
240V-1+N~50 Hz
2,5 mm²
6600 W
6000 W
6000 W
230V1+N connexion example (line 1 in the
table)
Jumpe
Phase
(brown)
In the event of an incorrect connection:
- option 1: your appliance does not work,
- option 2: the right cooking zones are inaccessible and
the power indicators blink.
ð check the position of the wires in the terminal board,
ð check that all screws are tight,
ð check the positioning of the jumpers.
This appliance conforms with the following European
Economic Community directives:
-
73/23/EEC of 19/02/73 (Low Voltage) and subsequent
modifications;
-
89/336/EEC
of
Compatibility) and subsequent modifications;
-
93/68/EEC of 22/07/93 and subsequent modifications
Attention: If the cooktop is installed above a built-in oven,
the electrical connection for the cooktop must be
independent of that for the oven, both for safety reasons
and to facilitate the removal of the oven for maintenance,
repair, etc.
10
Neutral
Earth
(blue)
(green/yellow)