Troubleshooting
Operation LED does not light
1. No power supply.
– Turn on the power.
2. Bad wiring connections or broken wire, short.
– Check wiring.
Receiver Alarm LED does not light when the beam
is broken.
1. No power supply.
– Turn on the power supply.
2. Bad wiring connections or broken wire, short.
– Check wiring.
3. Beam is reflected from another object and sent
to the Receiver.
– Remove the reflecting object or change
beam direction.
4. Two beams are not broken simultaneously.
– Break two beams simultaneously.
5. The beam interruption time is shorter than the
set response time.
– Set the response time shorter.
Receiver Alarm LED continues to light
1. Beam alignment is out.
– Check and adjust again.
2. Shading object between Transmitter and Receiver.
– Remove the shading object.
3. Optics of units are soiled.
– Clean the optics with a soft cloth.
4. Frequency channel is not compatible between
Transmitter and Receiver.
– Readjust to the same channel.
Intermittent alarm
1. Bad wiring connection.
– Check again.
2. Change of supply voltage.
– Stabilize supply voltage.
3. Shading object between Transmitter and Receiver.
– Remove the shading object.
4. A large electric noise source, such as a machine, is
located nearby Transmitter and Receiver.
– Change the position.
5. Unstable installation of Transmitter and Receiver.
– Stabilize.
6. Soiled optics of Transmitter and Receiver.
– Clean the optics with a soft cloth.
7. Improper alignment.
– Check and adjust again.
8. Small animals may pass through the two beams.
– Set the response time longer. (Impossible in a
site where an intruder can run at full speed)
4
Specifications
Detection system
Simulataneous breaking
. . . . . . . . . . . .
Infrared beam
. . . . . . . . . . . . . . . . . . . . . . .
Protection distance
– IS433 outdoor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
indoor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– IS434 outdoor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
indoor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– IS435 outdoor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
indoor
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Max. beam range
– IS433
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– IS434
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– IS435
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Response time
50msec. to 700msec.
. . . . . . . . . . . . . . . . . .
Supply voltage
12V to 30VDC (non–polarity)
. . . . . . . . . . .
Current consumption
– IS433
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– IS434
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– IS435
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Alarm output
Dry contact relay output
. . . . . . . . . . . . . . . . . .
Contact action: Interruption time +
delay time (1 to 3sec.)
Contact: 30V (AC/DC), 0,5A
Tamper output
Dry contact relay output
. . . . . . . . . . . . . . . .
Action: Activated when
Contact: 30V (AC/DC), 0,5A
Alarm LED
Red LED (Receiver)
. . . . . . . . . . . . . . . . . . . . . . .
ON: when an alarm is initiated
Attenuation LED
Red LED (Receiver)
. . . . . . . . . . . . . . . . .
ON: when beam is attenuated
Functions
Beam frequency changeover (4ch.),
. . . . . . . .
Monitor jack output, AGC circuit,
Ambient temperature
. . . . . . . . . . . . . . .
range
Mounting position
. . . . . . . . . . . . . . . . . . . .
Wiring
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Weight
– Transmitter
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– Receiver
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Appearance
. . . . . . . . . . . . . . . . . . . . . . .

Details for ordering

IS433 Photoelectric beam sensor (20m)
IS434 Photoelectric beam sensor (40m)
IS435 Photoelectric beam sensor (60m)
BP–60TE Pole cover (2pcs./set)
BP-60A Pole attachment for IS433/4/5
V54539-M101-A100
Limited Warranty
Vanderbilt products are warranted to be free from defects
in material and workmanship for 12 months from
original date of shipment. Our warranty does not cover
damage or failure caused by Acts of God, abuse,
misuse, abnormal usage, faulty installation, improper
maintenance or any repairs other than those provided
by Vanderbilt. All implied warranties with respect
to Vanderbilt, including implied warranties for
merchantability and implied warranties for fitness, are
limited in duration to 12 months from original date of
shipment. During the Warranty Period, Vanderbilt
will repair or replace, at its sole option, free of charge, any
defective parts returned prepaid. Please provide
the model number of the products, original date of
shipment and nature of difficulty being experienced.
There will be charges rendered for product repairs
made after our Warranty Period has expired.

EC Declaration of Conformity

Hereby, Vanderbilt International (IRL) Ltd declares that
this equipment type is in compliance with all relevant EU
of two beams
Directives for CE marking. From 20/04/2016 it is in
LED pulsed beam
compliance with Directive 2014/30/EU (Electromagnetic
Compatibility Directive.
20m
The full text of the EU declaration of conformity is
40m
available at:
40m
http://pcd.vanderbiltindustries.com/doc/Intrusion-
80m
accessories
60m
120m
200m
400m
600m
55mA
75mA
80mA
cover is detached
Frost proof cover
-25°C to +60°C
Indoor / Outdoor
Terminals
0.380kg
0.400kg
PC resin (wine red)
VBPZ:5299760001