Technical parameters
Inputs
Range of measurement of
lighting:
Detection angle:
Ouputs
Indication red LED:
Indication green LED RUN:
Communication
Interface:
Pover supply
From iNELS BUS:
Rated current:
From DALI BUS:
Rated current:
Dissipated power:
Connection
Terminals (mm
2
):
Operating conditions
Operating temperature:
Storing temperature:
Protection degree:
Operating position:
Dimension and weight
Dimension:
Weight:
Warning
Before the device is installed and operated, read this instruction manual carefully and with full
understanding and Installation Guide System iNELS3. The instruction manual is designated for
mounting the device and for the user of such device. It has to be attached to electro-installation
documentation. The instruction manual can be also found on a web site www.inels.com. Attention,
danger of injury by electrical current! Mounting and connection can be done only by a professional
with an adequate electrical qualifi cation, and all has to be done while observing valid regulations.
Do not touch parts of the device that are energized. Danger of life-threat! While mounting,
servicing, executing any changes, and repairing it is essential to observe safety regulations, norms,
directives and special regulations for working with electrical equipment. Before you start working
with the device, it is essential to have all wires, connected parts, and terminals de-energized. This
instruction manual contains only general directions which need to be applied in a particular
installation. In the course of inspections and maintenance, always check (while de-energized) if
terminals are tightened.
TECHNICAL SUPPORT | E-mail: support@inels.com | Mobil: +420 778 427 366 | Tel.: +420 573 514 276, +420 573 514 211 | Fax: +420 573 514 227 | www.inels.com
Made in Czech Republic
DLS3-1
1 - 100 000 lx
40 °
identifi cation DALI MASTER / setting indication
communications / unit status
Installation BUS iNELS
DALI
27 V DC, -20 / +10 %
12 mA (27V DC)
16 V (max. 23 V)
20 mA (16 V DC)
max. 0.5 W
max. 1x 2.5, max. 2x1.5 / with sleeve max. 1x 2.5
-30 .. +60 °C
-30 .. +70 °C
IP65
vertical
96 x 62 x 34 mm
100 g
ELKO EP, s.r.o. | Palackého 493 | 769 01 Holešov, Všetuly | Czech republic | e-mail: elko@elkoep.com
Communication protocol
24 bit DALI MASTER frame
Bit 23
Bit 22 – 17
Bit 16
0
64 short addresses
0
Instance number:
1
2
3
4
Light intenzity [Lux] = 10exp(Light intenzity step/174)
Supported DALI commands (IEC 62386-103:2014)
TERMINATE
INITIALIZE
RANDOMIZE
COMPARE
WITHDRAW
SEARCHADRH
SEARCHADRM
SEARCHADRL
PROGRAM_SHORT_ADDRESS
VERIFY_SHORT_ADDRESS
QUERY_SHORT_ADDRESS
DTR0
DIRECT_WRITE_MEMORY
IDENTIFY_DEVICE
SET_SHORT_ADR
ENABLE_WRITE_MEMORY
QUERY_DEVICE_STATUS
QUERY_VERSION_NUMBER
Bit 15
Bit 14 -10
1
32 instance numbers
event data
Event data DLS–3
Light intenzity step (1 sec)
Bit 9 – 0
2/2