Installation; Mechanical Installation - Festo DDPC Instrucciones De Utilizacion

Ocultar thumbs Ver también para DDPC:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 27
DDPC
• Make sure the compressed air is properly prepared (
• Maintain the selected medium for the total service life of the product.
Example: Always use non-lubricated compressed air.
• Pressurize your entire system slowly. There will then be no uncontrolled movements.
For slow start-up pressurisation, use start-up valve type HEL (
5

Installation

5.1

Mechanical installation

• Check the application of the DDPC:
– as a measuring cylinder
– with electronic control
Note
If the DDPC is used with electronic control:
• Use the DDPC only in the approved mounting positions
(
drive-specific information on the positioning controllers).
• To install the mechanical system, please observe the instructions in the descriptions
of the positioning controller.
• Make sure that tubing and connection accessories have sufficient space for movement.
If the cylinders are arranged parallel:
• Take the following minimum space requirements into account. Otherwise the magnetic fields of the
two cylinders will influence each other and lead to evaluation faults in the measuring system.
Parallel assembly
Bearing cap flush (Y = 0)
No minimum distance
Tab. 1
18
Offset assembly
Bearing cap offset (Y > 0)
Cable outlet between the
cylinders
Minimum distance X 70 mm
Technical data).
Accessories).
Cable outlet not between the
cylinders
Minimum distance X 60 mm
Festo – DDPC – 1207NH English