T16 - Curtain Release Time
When the power failure alarm is triggered, curtains will be released after the time set in this parameter has elapsed.
T17 - Time between curtain self-adjustments (if T01 = 0)
Allows the period between the two curtain adjustments to be configured. The curtain adjustment procedure consists of turning off all exhaust systems
and raising the curtain up to the maximum height (sum of all the steps). When the curtain is completely closed, the controller once again assumes
operation due to the exhaust systems that were in operation. This procedure allows occasional differences in the curtain's position to be corrected.

5.8 - Alarms

Operation parameters related to alarm outputs (
Fun
Low Temperature Alarm Differential
High Temperature Alarm Differential
Temperature Differential to Turn Alarm 1 Off
Low Humidity Alarm
Low Humidity Alarm Differential
Low Pressure Alarm
High Pressure Alarm
Pressure Alarms Differential
Alarm 1 Output Cycle Period
Delay time for power outage validation (Alarm 2).
Alarm 2 Output Cycle Period
A01 - Low Temperature Alarm Differential
Minimum temperature difference relative to setpoint to activateAlarm 1output.
A02 - High Temperature Alarm Differential
Maximum temperature difference relative to setpoint to activateAlarm 1output.
A03 - Temperature Differential to Turn Alarm 1 Off
Temperature difference to turn both High and Low TemperatureAlarms OFF.
A04 - Low Humidity Alarm
Minimum relative air humidity threshold to turn Low HumidityAlarm ON, triggeringAlarm 1 output.
A05 - Low Humidity Alarm Differential
Humidity Difference to turn the Low HumidityAlarm OFF.
A06 - Low Pressure Alarm
Minimum pressure value below whichAlarm 1output is triggered.
A07 - High Pressure Alarm
Maximum pressure value above whichAlarm 1output is triggered.
A08 - Pressure Alarms Differential
Pressure difference to turn both High and Low TemperatureAlarms OFF.
A09 - Alarm 1 Output Cycle Time
Cycle time in seconds forAlarm 1 output. If set to "0", the output will be permanently ON.
A10 - Delay time for power outage validation (Alarm 2).
Delay time in seconds for power outage validation (Alarm 2).
A11 - Alarm 2 Output Cycle Time
Cycle time in seconds forAlarm 2 output. If set to "0", the output will be permanently ON.
5.9 - Datalogger
Operation parameters relative to the controller's internal memory.
Fun
Overwrite Data Memory (0-no, 1-yes)
D01
Temperature Variation to Force Data Recording (0 = Off)
D02
Humidity Variation to Force Data Recording (0 = Off)
D03
Differential Pressure Variation to Force Data Recording (0 = Off)
D04
Time Lapse Between Samples
D05
Datalogger Operation Mode
D06
ALARM 1
and
ALARM 2
)
Description
Description
Min. Max.
0.0
0.0
33
Standard
CELSIUS
FAHRENHEIT
Unit
Standard
Min. Max.
0
1
-
1
0
1
5.0
°C
0.5
0
9
5.0
%UR
5.0
0.0
5.0
0
20
Pa
5
0
20
1
999
sec.
5
1
999
0
2
-
1
0
2
Standard
Unit
Standard
-
1
°F
1
%UR
5.0
PA
5
sec.
5
-
1