MODELS HLB9 & HLB11
IN-LINE BLOWERS
For use with Broan Elite and NuTone Premier Hoods.
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to pre-
vent backdrafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA), and the American
Society for Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage electri-
cal wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce the risk of fire, use only metal ductwork.
8. If this unit is to be installed over a tub or shower, it must be marked
as appropriate for the application and be connected to a GFCI
(Ground Fault Interrupter) - protected branch circuit.
9. Never place a switch where it can be reached from a tub or
shower.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when flambe-
ing food (i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef
Flambe').
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE AND
CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN - You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
!
FOR DOMESTIC COOKING ONLY
WARNING
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already
know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. If ventilator is installed in an unconditioned space (such
as an attic): Surround the ventilator with thermal insulation - to
minimize possible condensation.
4. Please read specification label on product for further information
and requirements.
TABLE OF CONTENTS
This manual is divided into sections as follows:
"TYPICAL INSTALLATION"
This section shows a common installation.
- Mounting (New Frame Construction)
- Mounting (Existing Frame Construction)
- Mounting Using Hanger Kit (included)
- Ducting (Horizontal blower discharge)
- Wiring
"MOUNTING OPTIONS"
"WIRING PLATE POSITION"
"DUCTING OPTIONS"
- Blower Discharge Positions
- Ducting (Vertical blower discharge)
"USE AND CARE"
"SERVICE PARTS"
"WARRANTY"
Installer: Leave this manual with
the homeowner.
Homeowner: Use and Care
information on page 4.
Page 1
!

Publicidad

loading

Resumen de contenidos para Broan HLB9

  • Página 1 Page 1 MODELS HLB9 & HLB11 IN-LINE BLOWERS For use with Broan Elite and NuTone Premier Hoods. READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 4. Use an extinguisher ONLY if: TO PERSONS, OBSERVE THE FOLLOWING: A. You know you have a Class ABC extinguisher and you already...
  • Página 2: Typical Installation

    Page 2 TYPICAL INSTALLATION TYPICAL INSTALLATION MOUNTING (New Frame Construction) MOUNTING USING HANGER KIT (included) 10” ROUND DUCT 8” X 12” TO 8” X 12” TO 8” X 12” TO (OUTLET) 10” ROUND 10” ROUND HANGER 10” ROUND TRANSITION TRANSITION KIT BOLT TRANSITION (FEMALE) (FEMALE) & WASHER (MALE) EXTENSION SPRING 10” ROUND DUCT HANGER 10” ROUND (INTAKE) KIT CHAIN DUCT (INTAKE) HANGER KIT EYE-BOLT...
  • Página 3: Mounting Options

    Page 3 WIRING PLATE POSITION WIRING BLACK BLACK EDGE OF HOUSING VERTICAL GROUND TO POWER CABLE WIRING PLATE CONNECTION WIRING PLATE HORIZONTAL POWER CABLE CONNECTION Wiring plate mounts to side or top of housing. WHITE WHITE 120 VAC LINE IN (from range hood) DUCTING OPTIONS Ventilator can be wired from outside of housing. Use UL approved connectors to wire per local codes.
  • Página 4: Service Parts

    This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties. To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
  • Página 5: Modelos Hlb9 Y Hlb11 Ventiladores Para Montaje En Línea

    MODELOS HLB9 Y HLB11 Página 5 VENTILADORES PARA MONTAJE EN LÍNEA Por uso con campanas de Broan Elite y NuTone Premier. LEA Y CONSERVE ESTAS INSTRUCCIONES PARA COCINAR EN CASA SOLAMENTE ADVERTENCIA ADVERTENCIA 4. Utilice un extinguidor SOLAMENTE si: PARA REDUCIR EL RIESGO DE INCENDIO, GOLPE ELÉCTRICO, O LESIÓN A PERSONAS, OBSERVE LO SIGUIENTE: A.
  • Página 6: Instalación Típica

    Página 6 INSTALACIÓN TÍPICA INSTALACIÓN TÍPICA MONTAJE (Estructura nueva) MONTAJE EL USAR KIT DE SUSPENDER (incluido) TRANSICIÓN 8” X 12” TRANSICIÓN (20,3 X 30,5 cm) A 8” X 12” TRANSICIÓN REDONDO DE 10” (20,3 X 30,5 cm) A TORNILLO Y DE 8” X 12” A (25,4) (MACHO) REDONDO DE 10” ARANDELA 10” REDONDA (25,4) (HEMBRA) DE KIT DE (20,3 x 30,5 cm SUSPENDER a 25,4 cm CONDUCTO...
  • Página 7: Colocación De La Placa De Conexiones

    Página 7 COLOCACIÓN DE LA PLACA CONEXIONES ELECTRICAS DE CONEXIONES NEGRO A PARTE SUPERIOR / NEGRO POSTERIOR DEL ENTO ALOJAMI TIERRA A LA PLACA DE CONEXIONES CONEXIÓN PLACA DE VERTICAL DEL CONEXIONES CABLE DE ALI- MENTACIÓN CONEXIÓN LÍNEA DE BLANCO HORIZONTAL ENTRADA DE DEL CABLE DE BLANCO 120 VCA ALIMENTACIÓN...
  • Página 8: Piezas De Servicio

    Esta garantía le proporciona derechos legales específicos, y usted puede también tener otros derechos, los cuales varían de estado a estado. Esta garantía reemplaza todas las garantías anteriores. Para calificar en la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio o al número de teléfono que se menciona abajo, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de cualquier defecto en el producto o pieza.
  • Página 9 MODÈLES HLB9 ET HLB11 Page 9 VENTILATEURS MONTAGE DANS LIGNE Pour usage avec Broan Elite et NuTone Premier hottes de cuissine. LIRE ET CONSERVER CES INSTRUCTIONS POUR USAGE DOMESTIQUE SEULEMENT AVERTISSEMENT AVERTISSEMENT POUR RÉDUIRE LE RISQUE D´INCENDIE, DE CHOC ÉLECTRIQUE OU DE 3.
  • Página 10: Installation Typique

    Page 10 INSTALLATION TYPIQUE INSTALLATION TYPIQUE MONTAGE (Construction en cours) MONTAGE EN UTILISANT LE KIT DE CINTRE (inclus) CONDUIT CIRCULAIRE DE 10 po (25,4 cm) (sortie) TRANSITION DE TRANSITION DE 8 x 12 po au 8 x 12 po au TRANSITION DE VIS ET 10 po circulaire (20,3 x 30,5 cm 10 po circulaire 8 x 12 po au RONDELLE DE au 25,4 cm circulaire) (mâle) (20,3 x 30,5 cm 10 po circulaire LE KIT POUR au 25,4 cm (20,3 x 30,5 cm au...
  • Página 11: Options De Montage

    Page 11 POSITION DE LA PLAQUE DE CÂBLAGE CÂBLAGE NOIR AU DESSUS / NOIR ARRIÈRE DU BOÎTIER FIL DE TERRE À PLAQUE DE CÂBLAGE BRANCHEMENT PLAQUE DU CÂBLE D’ A LIMENTATION CÂBLAGE À LA VERTICALE ENTRÉE BRANCHEMENT DU 120 VCA CÂBLE D’ A LIMENTATION BLANC (du le hotte) À L’HORIZONTALE BLANC La plaque de câblage se fixe sur le côté ou sur le dessus du Le ventilateur peut être branché...
  • Página 12: Utilisation Et Entretien

    GARANTIE LIMITÉE DE UN AN DE BROAN-NUTONE Broan-NuTone garantit à l’acheteur consommateur original de ses produits qu’ils sont exempts de vice de matériaux ou de fabrication pour une période d’un an à compter de la date d’achat original. IL N’Y A PAS D’AUTRES GARANTIES, EXPRIMÉES OU IMPLICITES, INCLUANT MAIS NON LIMITÉES AUX GARANTIES IMPLICITES DE QUALITÉ...

Este manual también es adecuado para:

Hlb11